57
T X DLY
NOR 008
(Advance d)
For use with external amplifiers that have slow relays; sets the time
from KEY OUT jack (active low) to first RF in 1-ms steps. To minimize loss of
QSK speed, use the shortest delay that works with your amp. Most will work with
the default (minimum) setting of 8 ms.
T X ESSB
[T]
OFF
(Advance d)
Extended SSB transmit bandwidth (
3 .0
,
3 . 5
,
4 .0
kHz, etc.) or
O FF
. See pg. 36.
T X INH
[T]
OFF
(Advance d)
If set to
LO = I NH
or
HI = I NH
, the operator can supply an external
logic signal to inhibit transmit. When inhibited, the T X LCD icon flashes.
T XGN{pwr}
[T]
00
(Troubleshooting.)
Shows transmit gain constant for the present band and power
mode, where {pwr} =
LP
(0-12W),
HP
(13-120W), or
M W
(0.1-1.5 mW). The
gain constant is updated whenever the
TU N E
function is activated on a given
band
at one of three specific power levels:
5.0 W, 50 W, and 1.00 milliwatt. See
transmit gain calibration procedure, pg. 48.
On 80 m with high power (> 13 W) selected, you should see
P R80
as part of the
TXGN
parameter display. T his indicates that the preamp is turned on during QRO
transmit on 80 m, and is the default. It should only be turned off for
troubleshooting purposes; this is done by tapping
P R E
.
If
TX ALC
(above) is
O FF
, the
TXGN
parameter can be set manually, at very
fine resolution. T his should only be done for troubleshooting purposes.
T XG VCE
[T]
0.0 dB
(Advance d)
Balances voice transmit peak power in relation to CW peak power
in
TU N E
mode. T ypically set between 0.0 to 1.5 dB.
VCO MD
[T]
SUB
NOR xx
(varies w/
VFO freq)
(Troubleshooting.)
VCO L-C range view/change/calibrate. Once the VCO is
calibrated (pg. 48), the parameter which appears here will include
NO R
at all
times. You can change the setting to troubleshoot VCO L-C ranges. When
finished, set the parameter back to
NO R 1 27
, then exit the menu and change
bands to restore the original setting.
Note:
In this menu entry only, the main/sub
receiver prefix (
RF
or
S UB
) is not displayed at all times. However, the
SUB
icon
will flash as usual when
S UB
is tapped.
VFO B->A
Function
Copi
es
VFO
B’
s
f
r
equency
t
o
VFO
A.
Cannot
be
us
ed
wi
t
hi
n
t
he
menu
i
t
s
el
f
;
must be assigned to a programmable function switch.
VFO CRS
Per-mode
Per-mode coarse tuning rate (hold
C O AR S E
and tune VFO A or B). Also applies
to the RIT /XIT tuning knob if
CONFIG:VFO OFS
is set to
O N
, and both RIT
and XIT are turned OFF.
VFO CT S
200
VFO counts per turn (
10 0
,
20 0
, or
4 00
). Smaller values result in easier fine-
tuning of VFO; larger values result in faster QSY.
VFO FST
50 Hz
Specifies the faster of the two VFO tuning rates (
R ATE
). The faster rate is
5 0
Hz
per step by default, but can be set to
20
Hz if desired. In this case,
VFO CTS
=
4 0 0
is recommended to ensure adequate fast-QSY speed.
VFO IND
NO
If set to
Y ES
, VFO B can be set to a different band than VFO A, which allows
listening to two bands at once (main/sub). See pg. 37 for independent main/sub
band considerations.
Note :
This menu entry is not available unless the sub
receiver is installed (see
CONFIG:KRX3
).
VFO OFS
OFF
If
O N
, the RIT /XIT offset control can be used to tune VFO A in large steps when
both
RI T
and
X I T
are turned off. T he step sizes vary with mode (see
VFO CRS
),
and are the same as the
C O AR S E
VFO tuning rates.
WMT R {pwr}
100
Wattmeter calibration parameter. {pwr} is the power mode:
LP
(0-12W),
HP
(13-120W), or
M W
(0.1-1.5 mW). See calibration procedure (pg. 48).
XVx ON
NO
Set to
YE S
to turn on transverter band x (
1
-
9
); tap
1
–
9
to select xvtr band.
Summary of Contents for K3