56
SER NUM
N/A
Your
K3’
s
s
er
i
al
number
,
e.
g.
0 20 0 0
. Cannot be changed.
SMT R OF
SUB
024
S-Meter offset; see calibration procedure (pg. 50).
SMT R SC
SUB
014
S-Meter scale; S-9 = 50 uV, S=3 = 1 uV with Preamp = ON, and AGC ON. See
calibration procedure (pg. 50).
SMT R PK
OFF
Set to
O N
for peak-reading S-meter.
SMT R MD
NOR
(Advance d)
S-meter mode: When set to
NO R
, preamp/attenuator settings will
affect the S-meter. (The default values of
SMTR OF
and
SMTR SC
apply to
NO R
.) If set to
ABS
, the S-meter reading will stay fairly constant with different
preamp/attenuator settings, but
SMTR OF
and
SMTR SC
must be carefully re-
aligned for both main and sub receivers.
SPLT SV
NO
If set to
Y ES ,
S PL I T
,
R I T
, and
X I T
on/off states are saved per-band.
SPKRS
1
Set to
2
if using two external speakers. T his enables binaural effects in
conjunction with the
AF X
switch, as well as stereo dual-receive if the sub
receiver is installed. For further details, see pg. 35.
SPKR+PH
NO
Y E S
= Speaker is ON, even when headphones are plugged into PHONES jack.
See detailed discussion on pg. 20.
SQ MAIN
0
This menu entry normally sets the main receiver squelch value (
0
-
2 9
). If VFO A
is rotated fully clockwise, the parameter changes to
=S UB P O T
. Squelch for
both main and sub receivers will then be controlled by the SUB RF/SQL knob,
and both main and sub RF gain will be controlled by the MAIN RF/SQL knob.
SQ SUB
0
This menu entry normally sets the sub receiver squelch value (
0
-
2 9
). But if
SQ MAIN
is set to
= S UB P O T
, then
SQ SUB
will also change to
=S UB P O T
.
Squelch for the sub receiver will then be controlled by the SUB RF/SQL knob,
and both main and sub RF gain will be controlled by the MAIN RF/SQL knob.
SW T EST
[T]
OFF
Changing the parameter displays
S CN ADC
. Hold any switch to see scan row
and switch ADC reading. Used for troubleshooting only.
SW T ONE
OFF
Sets up audible control annunciation (tones or audio Morse code).
SYNC DT
Function
(Advance d)
When SYNC DT (sync data) is activated in either SSB or DAT A
modes, T /R switching times are reduced to optimize for modes such as AMT OR
and
Pac
TOR.
The
“
-
S”
i
con
t
ur
ns
on.
Do not use SYNC DT for normal
SSB/DATA communications.
Cannot be changed within the menu; assign to a
programmable function switch. Also see
CONFIG:PTT RLS
(PTT release
delay).
TECH MD
OFF
Set to
O N
to enable
Tech Mode
menu entries (those marked with
[T]
in this list).
TIME
N/A
Real-time-clock view/set. Tap
1
/
2
/
3
to set HH / MM / SS. To see the time and
other displays during normal operation, tap
D I S P
(see pg. 36).
TTY LT R
Function
Performs an RTT Y FIGS to LT RS shift when the text decoder is enabled in
RTT Y modes. Cannot be changed within the menu itself; must be assigned to a
programmable function switch.
T UN PWR
NOR
If set to
NO R
,
TU N E
power level follows the POWER knob. Otherwise,
establishes a fixed power level for
TU N E
, overriding the present POWER knob
setting.
Note1:
TUN PWR
does not pertain to
ATU TU N E
, which always uses 5
or 10 W and is internally controlled.
Note2:
see
CONFIG:PWR SET
for per-
band power control.
T X ALC
[T]
ON
(Troubleshooting.)
Set to
O FF
to disable both
internal
and
external
transmit
ALC (overrides
EXT ALC
setting). Used when adjusting band-pass filters in TX
mode, or for troubleshooting. Set parameter to
O N
during normal operation.
Summary of Contents for K3