ATTENTION

! The solar installation is always ready for operation. Even when the water heater is

in the "Off" mode when there is heat in the solar collector, the circulation pump will be switched
on to discharge the heat!

To support the solar installation when there is insufficient heat, the water heater can use the heat
pump and electric heater. They are managed by a method aiming at using electricity only as a last
source. This way, with the least possible extra cost, you can be sure that you will always have hot
water, whether the sun is weak or there is not solar radiation at all.

Protective modes 

The protective modes are designed to protect the solar collector and boiler installations in the event 
of extreme operating conditions. Whether the boiler is switched on or off, and in which mode it works,
the thermostat monitors continuously both the temperature of the water in the water tank and of the 
solar collector. If necessary, a protection mode is activated from:

Protection against freezing of the solar collector.  

This protection transfers heat from the

boiler   to   prevent   the   installation   of   the   solar   collector   from   freezing.   It   is   triggered   at   a
measured   collector   temperature   below   the   setting   in   the   menu   "

Protect   Solar

"   item

"Temperature protection freezing"

. This function can be deactivated from the same menu

item 

"Solar protection freezing"

.

Protection   against   freezing   of   the   water   tank.  

The   electric   heater   is   switched   on   if   the

temperature in the water heater drops below 3 ° C

 

Overheating protection of the solar collector.  

If the solar collector temperature exceeds

90°C, the solar circulation pump will switch on regardless of the differential temperature. The
pump will shut off if the water temperature in the water heater exceeds 85 ° C.

Overheating protection at the top of the boiler. 

If the temperature measured by the upper

thermosensor   t2   exceeds   85   °   C,   the   electric   heater   will   shut   off   until   the   temperature
measured by the same thermosensor drops below the set temperature.

Automatically   activated   mode  

Vacation

  for   discharging   the   accumulated   heat   in   the   water

heater.   This   option   is   activated   with   the   marking   from   menu   "

Protect   Solar

"   item  

"Auto.

Vacation

". If after 21:00 the water temperature at the top of the boiler (measured by t2) is

above 77 ° C or if there is no hot water consumption until then, the temperature exceeds 60 °
C,  this mode activation will  be prepared.  Consequently,  in the  interval between 00:00 and
05:00, the solar pump will be switched on. The aim is to begin transferring heat from the water
heater to the solar collector and due to the existing energy losses on the pipes and in the solar
collector when there is no sun, the water in the water heater will cool down. So the next day will
again be able to accumulate new heat to cool down the solar collector. The pump will operate
until the temperature in the water heater drops below the setting in menu "

Protect Solar

", item

"

Min. temp. boiler

 ". This mode is indicated by the display 

Heat discharge

 in the upper blue

bar on the screen.

WARNING!

  When there is a risk of  temperature drop or overheating  of the collector,  it is

advisable not to disconnect the water heater from the
power supply grid!

Switching on / off of the water heater

To turn the water heater on or off, on the main screen, press

the On / Off button. The following selection menu will appear:
Use the up or down arrows to select what you want to do and
press Enter to confirm.

26

Summary of Contents for HPWH 120

Page 1: ...HEAT PUMP WATER HEATER 120 and 150 intended for wall mounting TECHNICAL DESCRIPTION INSTALLATION USE AND MAINTENANCE INSTRUCTIONS v20190723...

Page 2: ...kage into the atmosphere ATTENTION The connection of the indoor unit with a built in heat exchanger to the heat supply system solar and or other water heating systems using water or an aqueous solutio...

Page 3: ...and thus heats water Energy is extracted directly from the air A small amount of electricity is required to operate the compressor Heat pumps are made up of two parts an outdoor unit with a compresso...

Page 4: ...r tanks of the appliances are suitably protected against corrosion by means of a high quality enamel coating or high alloy chromium nickel steel Enamelled water tanks incorporate special alloy anodes...

Page 5: ...on of the installation and the connection of the heat exchanger of the water heater to it shall be performed only by qualified and competent companies with such subject of activity and in accordance w...

Page 6: ...he wall with the most suitable position with enough space to simplify the installation and maintenance of the outdoor unit Figure 1 b The outdoor unit shall be installed on a load bearing wall or non...

Page 7: ...e the shortest and as simple as possible way max 8 m long and 3 m elevation gain WARNING This is one of the conditions for the validity of the warranty d Protect pipes and cables to prevent damage ATT...

Page 8: ...system e Place the insulation on the pipes as first closing their openings in order to prevent any contamination getting inside them f Place the brass nuts on the pipes in the correct direction and m...

Page 9: ...1 4 Approximately 150 200 kgcm 15 20 Nm 9 52 mm 3 4 Approximately 350 400 kgcm 35 40 Nm Fig 8 CONNECTING OF THE REFRIGERANT PIPES WITH THE OUTDOOR UNIT Remove the protective plastic cover from the ou...

Page 10: ...age with a suitable detector Fig 11 CONNECTING OF THE INDOOR UNIT TO THE PLUMBING INSTALLATION Fig 12 The plumbing installation to which the indoor unit will be connected as well as the other elements...

Page 11: ...indoor unit to the plumbing system its water tank must be filled with water This is done in the following order Opethn the hot water tap on the farthest mixing cock Open the shut off valve 4 of Figur...

Page 12: ...y the company that has designed the project for installation and connecting the indoor unit It is imperative to install all equipment provided and or recommended by it in regard to safety control and...

Page 13: ...re the protective earth conductor if the cord is released from its attachment After connecting the appliance to the electrical system it is necessary to check its functionality WARNING Failure to comp...

Page 14: ...r 2 upper 15 Indoor unit 16 Magnesium anode 17 Thermal switch 18 Communication cable to the outdoor unit 19 Heater 20 Power supply of the appliance 21 Flange bracket 22 Wi Fi module optional 23 Solar...

Page 15: ...sconnected terminals The power supply cable to the UPS is connected to the terminals Lout phase and Nout zero The output of the UPS is connected to the terminals Lin phase and Nin zero WARNING It is i...

Page 16: ...el coating should not be removed but only wiped with dry cotton cloth without the use of rigid tools Regular removal and cleaning of limestone is essential for the reliability of the appliance It is d...

Page 17: ...special valve is integrated in the combined valve which in normal operation of the indoor unit allows the water expanded during its heating not to drip through the side opening of the valve but to en...

Page 18: ...es 8 Information field 9 Air temperature around the heat pump 10 Heat pump When the heat pump is switched on the blade moves Main screen appliances with heat exchanger 1 Additional features of the boi...

Page 19: ...f the solar If the solar thermal sensor does not work the solar circulation pump will be switched on continuously to avoid overheating of the solar installation Vacation The boiler is in a manually ac...

Page 20: ...the graphs with the average water temperature at the top of the boiler The first three types of graphics are for the last 4 days and the average temperature graphs are for the last 2 days These chart...

Page 21: ...inlet temperature 3 Position of EEV 4 Supply voltage 5 Current 6 Power Consumption 7 Evaporator temperature 8 External ambient temperature 9 Heat pump condition 10 Compressor condition 11 Fan conditio...

Page 22: ...ng the day Vacation Mode Freeze protection solar Activated mode for protection of the solar panel against freezing Freeze protection boiler Activated mode for protection of the boiler against freezing...

Page 23: ...t Damaged Flash A malfunction of the microcontroller resulting in the failure to record the settings in the non volatile memory i e changes to settings are lost when power supply is lost Update Outdoo...

Page 24: ...red The heat pump stops working until the voltage has reached the allowable range High current Current exceeds 7 5A The heat pump stops but can be switched on again after the compressor re start prote...

Page 25: ...all the necessary adjustments to the parameters in the selected menu are made pressing the On Off Back button goes to the previous screen WARNING If you do not change anything for a longer period bet...

Page 26: ...p will switch on regardless of the differential temperature The pump will shut off if the water temperature in the water heater exceeds 85 C Overheating protection at the top of the boiler If the temp...

Page 27: ...when the desired temperature can not be achieved with other heat sources for example at a set temperature above the heat pump maximum allowable or if there is another problem with the heat pump operat...

Page 28: ...by the heat pump and the electric heater The set temperature adjustment ranges are from 20 to 75 C When setting a temperature that exceeds the heat pump allowance the heating is done only with the ele...

Page 29: ...t reduction in electricity costs a low temperature can be set from the Temperature Setting and only in the required time intervals via the timer to switch on the heat pump forcedly and or the electric...

Page 30: ...ghtness of the display Field Anode will define the presence of Anode Protection if the boiler is made of stainless steel there is no anode protection The Power field adjusts the power of the power hea...

Page 31: ...nterrupted its clock is maintained for up to 24 hours If the power is turned off for an extended period of time the clock stops and the next time it is turned on it must be reset WARRANTY WARRANTY TER...

Page 32: ...hange of the shape dimensions and location of parts and components that are exposed to an impact which is not in accordance with its normal use Lost profits tangible and intangible damages caused by t...

Reviews: