background image

The safety valve, if necessary, also serves to drain water from the water tank. This is done as follows:

The indoor unit is switched off from the electric grid by means of the auxiliary device and, for
safety reasons, the electric fuse in the phase circuit to the water heater is switched off.

Cold water supply to the appliance is stopped - close the crane (4 of Figure 12).

Open the hot water tap of the mixing cock or disconnect the hot water pipe (outlet pipe) of the
water heater.

Lift the combined valve lever (5 in Figure 12) and wait until no more water leaks out of the
valve opening.

These actions do not ensure the  complete emptying of water from the water tank. This is performed
only   by   a   specialist   because   it   involves   disconnecting   the   electrical   circuit   of   the   appliance   and
removing the flange of the water tank.

WARNING

! IT IS STRUCTLY FORBIDDEN to turn on the power supply of the indoor unit while

the   water   tank   is  partially   or  completely   emptied  of  the  water!   Before  recommissioning  the
APPLIANCE, remember to fill the water tank first.

WARNING

! It is forbidden to circulate the heat carrier through the heat exchanger of the indoor

unit with partially or completely emptied water tank.

WARNING

! When draining water from the water tank, it is necessary to take all necessary

measures to prevent damage from drained water.

CONNECTION   OF   THE  INDOOR   UNIT  WITH   HEAT   EXCHANGER   TO   THE
INSTALLATION OF THE ADDITIONAL HEAT SOURCE

The indoor unit with a heat exchanger is connected to the alternative heat source while fulfilling all
the requirements of the special additional instructions provided by the company that has designed the
project for installation and connecting the indoor unit. It is imperative to install all equipment, provided
and / or recommended by it, in regard to  safety, control and  controlling the movement of the heat
carrier. 

WARNING

! It is forbidden to install shut-off valves simultaneously at both ends (the inlet and

outlet) of the heat exchanger.  In the event that  the indoor unit heat exchanger  would not be
used  temporarily and is not connected to the heat source installation, it should be filled with
propylene glycol solution suitable for heating systems.

The connection of an indoor unit with a heat exchanger to the additional heat source is performed
only by qualified technicians from a specialized company in accordance with the project developed by
it.

CONNECTION TO THE POWER SUPPLY INSTALLATION 

WARNING

! Do not connect the indoor unit to the power supply system before making sure that

the water tank is full of water! Check it out! 

The indoor unit is an appliance with a degree of protection against damage from  electrical current
“Class I”, which requires its compulsory connection to the earthing circuit of the electrical installation.
The power supply to the indoor unit is 230 V ~ and is carried out by means of a separate circuit with a
three-core insulated cable with a cross-section of each wire 2.5 mm

2

 (phase, neutral and protective).

If   the  cable   from   the  electrical  installation   of   the   room   is  two-core,   a   specialist   must   install   an
additional protective conductor, which should not be cut off anywhere from the electrical board to the
water heater. If the protective conductor/wire has intermediate connections, the latter must be reliably
secured  against self-loosening. Otherwise, the appliance  will not be properly  secured, which  will
reduce its safety

12

Summary of Contents for HPWH 120

Page 1: ...HEAT PUMP WATER HEATER 120 and 150 intended for wall mounting TECHNICAL DESCRIPTION INSTALLATION USE AND MAINTENANCE INSTRUCTIONS v20190723...

Page 2: ...kage into the atmosphere ATTENTION The connection of the indoor unit with a built in heat exchanger to the heat supply system solar and or other water heating systems using water or an aqueous solutio...

Page 3: ...and thus heats water Energy is extracted directly from the air A small amount of electricity is required to operate the compressor Heat pumps are made up of two parts an outdoor unit with a compresso...

Page 4: ...r tanks of the appliances are suitably protected against corrosion by means of a high quality enamel coating or high alloy chromium nickel steel Enamelled water tanks incorporate special alloy anodes...

Page 5: ...on of the installation and the connection of the heat exchanger of the water heater to it shall be performed only by qualified and competent companies with such subject of activity and in accordance w...

Page 6: ...he wall with the most suitable position with enough space to simplify the installation and maintenance of the outdoor unit Figure 1 b The outdoor unit shall be installed on a load bearing wall or non...

Page 7: ...e the shortest and as simple as possible way max 8 m long and 3 m elevation gain WARNING This is one of the conditions for the validity of the warranty d Protect pipes and cables to prevent damage ATT...

Page 8: ...system e Place the insulation on the pipes as first closing their openings in order to prevent any contamination getting inside them f Place the brass nuts on the pipes in the correct direction and m...

Page 9: ...1 4 Approximately 150 200 kgcm 15 20 Nm 9 52 mm 3 4 Approximately 350 400 kgcm 35 40 Nm Fig 8 CONNECTING OF THE REFRIGERANT PIPES WITH THE OUTDOOR UNIT Remove the protective plastic cover from the ou...

Page 10: ...age with a suitable detector Fig 11 CONNECTING OF THE INDOOR UNIT TO THE PLUMBING INSTALLATION Fig 12 The plumbing installation to which the indoor unit will be connected as well as the other elements...

Page 11: ...indoor unit to the plumbing system its water tank must be filled with water This is done in the following order Opethn the hot water tap on the farthest mixing cock Open the shut off valve 4 of Figur...

Page 12: ...y the company that has designed the project for installation and connecting the indoor unit It is imperative to install all equipment provided and or recommended by it in regard to safety control and...

Page 13: ...re the protective earth conductor if the cord is released from its attachment After connecting the appliance to the electrical system it is necessary to check its functionality WARNING Failure to comp...

Page 14: ...r 2 upper 15 Indoor unit 16 Magnesium anode 17 Thermal switch 18 Communication cable to the outdoor unit 19 Heater 20 Power supply of the appliance 21 Flange bracket 22 Wi Fi module optional 23 Solar...

Page 15: ...sconnected terminals The power supply cable to the UPS is connected to the terminals Lout phase and Nout zero The output of the UPS is connected to the terminals Lin phase and Nin zero WARNING It is i...

Page 16: ...el coating should not be removed but only wiped with dry cotton cloth without the use of rigid tools Regular removal and cleaning of limestone is essential for the reliability of the appliance It is d...

Page 17: ...special valve is integrated in the combined valve which in normal operation of the indoor unit allows the water expanded during its heating not to drip through the side opening of the valve but to en...

Page 18: ...es 8 Information field 9 Air temperature around the heat pump 10 Heat pump When the heat pump is switched on the blade moves Main screen appliances with heat exchanger 1 Additional features of the boi...

Page 19: ...f the solar If the solar thermal sensor does not work the solar circulation pump will be switched on continuously to avoid overheating of the solar installation Vacation The boiler is in a manually ac...

Page 20: ...the graphs with the average water temperature at the top of the boiler The first three types of graphics are for the last 4 days and the average temperature graphs are for the last 2 days These chart...

Page 21: ...inlet temperature 3 Position of EEV 4 Supply voltage 5 Current 6 Power Consumption 7 Evaporator temperature 8 External ambient temperature 9 Heat pump condition 10 Compressor condition 11 Fan conditio...

Page 22: ...ng the day Vacation Mode Freeze protection solar Activated mode for protection of the solar panel against freezing Freeze protection boiler Activated mode for protection of the boiler against freezing...

Page 23: ...t Damaged Flash A malfunction of the microcontroller resulting in the failure to record the settings in the non volatile memory i e changes to settings are lost when power supply is lost Update Outdoo...

Page 24: ...red The heat pump stops working until the voltage has reached the allowable range High current Current exceeds 7 5A The heat pump stops but can be switched on again after the compressor re start prote...

Page 25: ...all the necessary adjustments to the parameters in the selected menu are made pressing the On Off Back button goes to the previous screen WARNING If you do not change anything for a longer period bet...

Page 26: ...p will switch on regardless of the differential temperature The pump will shut off if the water temperature in the water heater exceeds 85 C Overheating protection at the top of the boiler If the temp...

Page 27: ...when the desired temperature can not be achieved with other heat sources for example at a set temperature above the heat pump maximum allowable or if there is another problem with the heat pump operat...

Page 28: ...by the heat pump and the electric heater The set temperature adjustment ranges are from 20 to 75 C When setting a temperature that exceeds the heat pump allowance the heating is done only with the ele...

Page 29: ...t reduction in electricity costs a low temperature can be set from the Temperature Setting and only in the required time intervals via the timer to switch on the heat pump forcedly and or the electric...

Page 30: ...ghtness of the display Field Anode will define the presence of Anode Protection if the boiler is made of stainless steel there is no anode protection The Power field adjusts the power of the power hea...

Page 31: ...nterrupted its clock is maintained for up to 24 hours If the power is turned off for an extended period of time the clock stops and the next time it is turned on it must be reset WARRANTY WARRANTY TER...

Page 32: ...hange of the shape dimensions and location of parts and components that are exposed to an impact which is not in accordance with its normal use Lost profits tangible and intangible damages caused by t...

Reviews: