26
This command switches the output ON for a set period of time and switches the output back
to OFF after the set period of time is over.
This command switches the output OFF for a set period of time and switches the output back
to ON after the set period of time is over.
Turn ON Output
by Pulse
Turn OFF Output
by Pulse
SMS text:
XXXX_Cx:ON:T
or
XXXX_OutputName:ON:T
Value
: T – period of time in seconds, range - [1-9999]
Example:
1111_C3:ON:75
SMS text:
XXXX_Cx:OFF:T
or
XXXX_OutputName:OFF:T
Value
: T – period of time in seconds, range - [1-9999]
Example:
1111_Pump:OFF:50
The delay period of time between telephone line failure and restore events. If telephone line
failure and restore events occur before the set delay period of time is over, the system will not
send the SMS report.
Telephone Line
Failure/Restore Delay
SMS text:
XXXX_TELDLY:T
Value:
T – period of time in seconds, range - [1-250]
This command provides a list of SMS message structure examples supported by ET082.
List SMS Message
Structure
SMS text:
XXXX_HELP
Example:
1111_HELP