![Eldes ET082 User Manual Download Page 23](http://html1.mh-extra.com/html/eldes/et082/et082_user-manual_2377656023.webp)
User manUal elDes eT082 v1.2
23
6.2.3 Ending the Configuration Process
After the system configuration is complete, use one of the following methods to end the con-
figuration process:
- Press
Disconnect
button and close
ELDES Configuration Tool
software;
- Wait for the system to reply with an SMS message confirming the end of the session;
- Shut down the connection with the server at any time by sending an SMS message.
Shut down the
Connection with
the Server
6.3 Configuration Parameter Set (SMS)
SMS report indicating information on system input and output status.
Status
SMS text:
XXXX_STATUS
Example:
1111_STATUS
SMS text:
XXXX_ENDCONFIG
Example:
1111_ENDCONFIG
The 4-digit SMS password intended for system configuration and control by SMS messages.
By default, the SMS password is
0000
(four zeros) which is recommended to change.
The system supports up to 3 phone number entries allowing to receive input alarm and res-
tore texts by SMS.
User 1
phone number is mandatory while other phone number entries
are not necessary. All numbers must be entered starting with international country code e.g.
44[area code][local number]. The
plus
symbol is not necessary.
Set SMS Password
Set User Phone
Number
SMS text:
0000_PSW:XXXX
Value:
XXXX – new 4-digit SMS password.
Example:
0000_PSW:1111
SMS text:
XXXX_NRx:3701111111
Value:
NRx: - user phone number entry, range - [NR1... NR3]
Example:
1111_NR1:37062222222