24
Each input has an alarm text which is sent by SMS message to a preset user (-s) in case the
input is violated. Manufacturer default input alarm text:
Z1 - Input 1 TRIGGERED, Z2 - Input 2
TRIGGERED, Z3 - Input 3 TRIGGERED.
This command sets an alarm text for a specified input. Maximum allowed length is 23 charac
-
ters including
space
characters.
Each input has a restore text which is sent by SMS message to a preset user (-s) in case the
input is restored. Manufacturer default input restore texts:
Z1 - Input 1 RESTORED, Z2 - Input 2
RESTORED, Z3 - Input 3 RESTORED.
This command sets a restore text for a specified input. Maximum allowed length is 23 charac-
ters including
space
characters.
This command disables a specified input. By default, all inputs are enabled.
Set Input Alarm Text
Set Input
Restore Text
Disable Input
SMS text:
XXXX_TZx:ON:NewAlarmText
Value:
TZx - input number, range - [TZ1... TZ3].
Example:
1111_TZ3:ON:Sensor violated
SMS text:
XXXX_TZx:OFF:NewAlarmText
Value:
TZx - input number, range - [TZ1... TZ3].
Example:
1111_TZ3:OFF:Sensor restored
SMS text:
XXXX_Zx:OFF
Value:
Zx - input number, range - [Z1... Z3]
Example
: 1111_Z3:OFF