User manUal elDes eT082 v1.2
11
5. Communication Modes & Methods
ET082 communicator supports
Basic
and
Advanced
modes & methods providing a variety of communication protocols.
Basic
mode
is recommended when only one communication method is required while
Advanced
mode is recommended to use when one or
more backup communication methods are required. Please note, that some protocols are not supported in
Basic
mode and vice
versa.
COMMUNICATION MODES & METHODS
Basic Mode
Advanced Mode
Method
Protocol
Method
Protocol
Voice Calls (GSM audio - direct
channel)
Ademco Contact ID®, 4+2
Voice Calls (GSM audio - data
buffering)
Ademco Contact ID®,
Scancom
SMS (up to 5 users)*
Ademco Contact ID®
(converted to user-
understandable text)
SMS (up to 5 users)*
Ademco Contact ID®
(converted to user-
understandable text)
GPRS (1 destination IP address)
EGR100, Kronos, SIA IP
GPRS (up to 3 destination IP
addresses)
EGR100, Kronos, SIA IP
Voice Calls (GSM audio - direct
channel) + SMS (up to 5 users)*
Ademco Contact ID® (by
SMS: converted to user-
understandable text)
CSD (fax line)
* SMS messages are sent to the preset user phone number (-s) set in
ELDES Configuration Tool
software.
5.1 Wiring Diagrams
ATTENTION:
Before connecting ET082 power supply to alarm system‘s auxiliary output (AUX), please, make sure that the
output is able to maintain peak curent consumption of up to 700mA max. Otherwise, please, use an external power supply
for ET082.
Before configuring communication methods, the user must decide whether direct data transmission from alarm system to mo-
nitoring station via PSTN and PSTN status monitoring is required or not. This is defined by a respective circuit wiring and jumper
presence on
JP8/JP9
PCB pins.
NOTE:
PSTN is always a primary (master) connection and it cannot be set as backup when used.