Eldes ET082 User Manual Download Page 2

Copyright © “ELDES UAB”, 2012. All rights reserved.

It is strictly forbidden to copy and distribute information in this document or pass to a third party without an advanced written authorization from 

“ELDES UAB”. “ELDES UAB” reserves the right to update or modify this document and/or related products without a warning. Hereby, „ELDES UAB“ 

declares that this GSM/GPRS communicator ET082 is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/

EC. The declaration of conformity may be consulted at www.eldes.lt

User Manual v1.2

Safety instructions

Please read and follow these safety guidelines in order to maintain safety of operators and people around:

•    GSM/GPRS communicator ET082 (further referenced as system, device or communicator) contains a radio transceiver operating 

in GSM850/900/1800/1900 bands. 

•   DO NOT use the system where it can interfere with other devices and cause any potential danger.

•  DO NOT use the system with medical devices if this is required in the manual of the medical device.

•   DO NOT use the system in hazardous environment.

•   DO NOT expose the system to high humidity, chemical environment or mechanical impacts.

•   DO NOT attempt to personally repair the system.

•   System labelling sticker is at the bottom of the device.

System ET082 is a device mounted in limited access areas. Any system repairs must be done only by qualified, safety aware 

personnel.

Mains power must be disconnected before any installation or tuning work starts. The system installation or maintenance 

must not be done during stormy conditions.

The system must be powered by main 10-24V 

  300mA power supply which must be approved by LST EN 60950-1 stan-

dard and be easily accessible.

Any additional devices linked to the system ET082 (computer, sensors, relays etc.) must be approved by LST EN 60950-1 

standard.

External power supply can be connected to AC mains only inside ins

-

tallation room with automatic 2-pole circuit breaker capable of discon

-

necting circuit in the event of short circuit or over-current condition. 

Open circuit breaker must have a gap between connections of more 

than 3mm and the disconnection current is 5A. 

Fuse F1 model - miniSMDC 500mA. Blown fuse cannot be replaced by the user and the replacement fuses have to be exactly 

the same as indicated by the manufacturer.

The device is fully turned off by disconnecting 2-pole switch off device of the external power supply or any other linked 

device that the system ET082 is powered from.

The WEEE (Waste Electrical and Electronic Equipment) marking on this product (see left) or its documentation indicates that the pro

-

duct must not be disposed of together with household waste. To prevent possible harm to human health and/or the environ ment, the 

product must be disposed on in an approved and environmentally safe recycling process. For further information on how to dispose 

of this product correctly, contact the system supplier, or the local authority responsible for waste disposal in your area.

Phase

AC 230V

50 Hz/DC 24V

USB cable

Null

ET082

PE

Summary of Contents for ET082

Page 1: ...GSM GPRS COMMUNICATOR ET082...

Page 2: ...t be disconnected before any installation or tuning work starts The system installation or maintenance must not be done during stormy conditions The system must be powered by main 10 24V 300mA power s...

Page 3: ...vice It is very impor tant to read the user manual before starting to use the system Contents 1 General Information 4 1 1 Operation Description 4 2 Technical Specifications 6 2 1 Electrical Mechanical...

Page 4: ...channel Voice Calls GSM audio channel and or to users via SMS message GPRS network CSD fax line ET082 main applications features Property security Data re transmission to monitoring station via GSM GP...

Page 5: ...or Input Output Control 3 Number of Low Level Negative Digital Inputs 3 Allowable Input Values Voltage 0 1 45V current 0 8 0 6mA Input Type NO normally open Number of Outputs 3 Output C1 C3 Circuit Ma...

Page 6: ...ing factory default settings SET For communication method of Basic mode set up MODE For communication method of Basic mode set up JP8 JP9 For direct data transmission via PSTN with status monitoring U...

Page 7: ...rs of ET082 and alarm system unit must be connected ET082 inputs Z1 Z3 are connected to PGM outputs of alarm system unit if PGM output is im plemented as open collector circuit or any other circuit an...

Page 8: ...It is not recommended to turn on the device without GSM antenna connec ted NOTE It is recommended to install the GSM antenna away from the alarm system to ensure better quality of the audio signal It...

Page 9: ...com Scancom Kronos Kronos Kronos Kronos EGR100 EGR100 EGR100 EGR100 SIA IP SIA IP SIA IP SIA IP Primary Voice Calls Voice Calls Voice Calls SMS SMS SMS GPRS 1 3 GPRS 1 3 GPRS 1 3 CSD CSD CSD N A N A B...

Page 10: ...N or GSM is restored For more details please refer to ELDES Configuration Tool software s HELP section ET082 can also detect temporary service suspension by the service provider for technical or billi...

Page 11: ...le text GPRS 1 destination IP address EGR100 Kronos SIA IP GPRS up to 3 destination IP addresses EGR100 Kronos SIA IP Voice Calls GSM audio direct channel SMS up to 5 users Ademco Contact ID by SMS co...

Page 12: ...PSTN Connection With this wiring the communicator retransmits data from alarm system to monitoring station via landline PSTN 1 Connect the circuit as indicated in Fig No 5 connect telephone contacts o...

Page 13: ...landline PSTN of PBX 4 Connect power supply to DC COM contacts Power supply is usually used as AUX and AUX output of alarm system 5 NO jumpers have to be set on JP8 JP9 pins 5 2 Basic Mode The communi...

Page 14: ...ftware s HELP section 5 2 2 SMS Method ATTENTION It is necessary to set monitoring station phone number on alarm system for SMS method In such case you can use any number one digit is enough By this m...

Page 15: ...on Tool software 3 Configure Ademco Contact ID data message structure using ELDES Configuration Tool software if required For more details please refer to ELDES Configuration Tool software s HELP sect...

Page 16: ...vailable protocols Kronos Kronos LT Kronos NET monitoring station software data format EGR100 EGR100 GPRS software data format SIA IP SIA IP data format complying with ANSI SIA DC 09 2007 standard 3 S...

Page 17: ...it to me mory buffer and transmits it to monitoring station via GSM audio channel Set the following ET082 parameters using ELDES Configuration Tool software 1 Switch to Advanced mode by enabling Backu...

Page 18: ...Add user phone number s 5 Configure Ademco Contact ID data message structure if required For more details please refer to ELDES Configuration Tool software s HELP section If PSTN connection is used t...

Page 19: ...ftware Port Forwarded TCP UDP port number for the computer running Kronos EGR100 software Protocol Format of the data message transmitted from ET082 to monitoring station by GPRS method Available pro...

Page 20: ...p 1 and Backup 2 connections if required 4 Set CSD monitoring station phone number For more details please refer to ELDES Configuration Tool software s HELP section If PSTN connection is used the comm...

Page 21: ...ameter and value For some parameters the value does not apply i e STATUS Software ELDES Configuration Tool is intended to work directly with ET082 system which can be connected to the computer via USB...

Page 22: ...ost name and port number are saved in the device memory after the first successful connection 6 2 2 Connecting to ELDES Configuration Server using ELDES Configuration Tool Software 5 3 2 1 Run ELDES C...

Page 23: ...S Example 1111_STATUS SMS text XXXX_ENDCONFIG Example 1111_ENDCONFIG The 4 digit SMS password intended for system configuration and control by SMS messages By default the SMS password is 0000 four zer...

Page 24: ...nufacturer default input restore texts Z1 Input 1 RESTORED Z2 Input 2 RESTORED Z3 Input 3 RESTORED This command sets a restore text for a specified input Maximum allowed length is 23 charac ters inclu...

Page 25: ...default output names C1 Output1 C2 Output2 C3 Output3 This command sets at name for a specified output Maximum allowed length is 23 characters Enable Input Set Output Name SMS text XXXX_Zx ON Value Z...

Page 26: ...9999 Example 1111_C3 ON 75 SMS text XXXX_Cx OFF T or XXXX_OutputName OFF T Value T period of time in seconds range 1 9999 Example 1111_Pump OFF 50 The delay period of time between telephone line failu...

Page 27: ...It is strongly recommended to restore parameters to default values after the firmware upgrade process 7 3 Technical Support Indication Possible Reason GSM LED is off or not flashing No external power...

Page 28: ...28 8 Related products ET08P plastic enclosure Power supply...

Page 29: ...User manual ELDES ET082 v1 2 29...

Page 30: ...Made in Lithuania www eldes lt...