Helpful advice
Euro-2100
© Elcom, s. r. o.
63
What to do in case of power failure?
Power failure
This part is important only for registers that
operate without the built-in accumulator.
If you have used the register and a power failure
occurs, it is necessary:
• to switch the register off
• after electric power recovery switch on the
register
• if the register displays the text
Continue
on Sale
it is necessary to complete the
purchase and compare the resulting sum
with the total of registered items within the
purchase; if one of the items has not been
added to the total sum of the purchase but
it was sold to the customer it is necessary to
register it additionally.
Failures of register as a result of
interference in power network
Accidental failures of electronic equipment are
frequently caused by the power network or by
electromagnetic interference. In case of inten-
sive interference in your working area, or in case
of over or under voltage, installation of protec-
tive devices can help significantly. Ask your au-
thorised dealer or service technician for help.
What to do in case of “Low BAT., finish sale ” signal
Displaying of the
Low BAT., finish
sale
warns the operator about discharging
the built-in accumulator.
The stage of internal accumulator charge de-
fines the percentage value in the upper left
corner of the operators display. This percent-
age value informs also that power supply of the
ECR is internal accumulator (the external en-
ergizer is not connected). In case the charge is
low (higher percentage value) the ECR displays
the text
Low BAT., finish sale
for a
short time and peeps alerting tone (e. g. by re-
ceipt printing when current input is higher). If
the discharge is higher (percentage value is low)
the text
Low BAT., finish sale
is dis-
played all the time and the ECR peeps alerting
and interrupted tone. After this warning the
cash register can print about hundred receipts.
It is necessary:
• to register the purchase
• to connect the register to the external
adapter
• if it is not possible to connect the register to
the adapter, you should turn it off and start
to use it only after connecting the adapter
or battery box
Long-term usage of the register when
Low
BAT., finish sale
is signalled can re-
sult in decreasing the accumulator lifetime or
in damaging the register. If the internal accu-
mulator is very discharged and you want to
charge it by the external adaptor, first of all be
sure that ECR is turned off, then connect the
external adaptor for at least 15 minutes (ECR is
off ). The internal accumulator is charging even
the ECR is turned off.
Care of internal battery:
• a complete battery charge takes 4-5 hours.
• we suggest to charge a battery to 100 and
use it till cash register starts to signalize the
battery charge requirement. Repeat this
process three times at least (it elongates an
endurance of the battery).
• we suggest to change the battery in case of
the battery decrease, e. g. shorter work cy-
cle of the ECR after a battery charge.
• provide a battery charging only with a con-
nected network.
10%
Low BAT., finish sale
Summary of Contents for Euro-2100
Page 1: ...Euro 2100 User manual manual version 1 0...
Page 65: ...Euro 2100 Elcom s r o Notes...
Page 66: ...Euro 2100 Elcom s r o Notes...
Page 67: ...Euro 2100 Elcom s r o Notes...
Page 68: ...Euro 2100 Elcom s r o Notes...