07/2009 - Art. Nr. 4200 1023 3700A
36
Start-up
Adjustment mode
Menu “PARAMETER”
Presetting the burner
o
"PROGRAM"
In the "PROGRAM" menu, points P9/P3/P1/P0/P2/P4 can be preset in accordance
with the adjustment table (page 10) for the required burner output. The control unit
then switches to the "SETTING" menu.
• Access to the setting mode.
• Select "PROGRAM" via
or
.
• Confirm with
.
Adjusting the air value.
• Place the cursor in the air position, using
or
.
• Activate via
(the cursor flashes).
• Set the new value using
or
.
• Confirm with
.
Changes between setting points P9/P3/P1/P0/P2/P4.
• Place the cursor on “NEXT” or “PREVIOUS” using
or
.
• Confirm with
.
Direct access to this menu is possible via setting mode, by selecting "SETTINGS"
p
.
o
NEXT
AIR: .. ‘ . FUEL OIL:
MAX. POWER SETTING
NEXT
AIR: .. ‘ . FUEL OIL:
MEDIUM SETTING
NEXT PREVIOUS
AIR: .. ‘ . FUEL OIL:
MINIMUM SETTING
NEXT PREVIOUS
AIR: .. ‘ . FUEL OIL:
IGNITION SETTINGS
NEXT PREVIOUS
AIR: FUEL: .. ‘ .
MEDIUM VALVE SUPPLY
NEXT PREVIOUS
AIR: FUEL: .. ‘ .
MAX VALVE SUPPLY
?
?
?
?
?
?
SETTINGS
COMBUSTION
READY TO BEGIN
?