32
Product data sheet ErP
www.elco.net
TRIGON L
en
Product data about the directive and regulation 2010/30/EU
(EU) 811/2013
TRIGON L
65
Seasonal space heating energy efficiency class
Rated heat output
P
rated
kW
59
Seasonal space heating energy efficiency
η
s
%
92
Sound power level, indoors/ outdoors
LWA
dB
52
TRIGON L
65
Class VI
, with use of components:
-
TRIGON L
-
Room temperature sensor
QAA 73/75 (option)
-
External temperature sensor QAC 34
Temperature controller contribution to
η
s: 4%
η
s
%
92+4= 96
Class V
, with use of components:
-
TRIGON L
-
Room temperature sensor
QAA 73/75 (option)
Temperature controller contribution to
η
s: 3%
η
s
%
92+3= 95
Class II
, with use of components:
-
TRIGON L
-
External temperature sensor QAC 34
Temperature controller contribution to
η
s: 2%
η
s
%
92+2= 94
Important:
The installation, consisting of the boiler and all accessories including temperature control, together define the seasonal heating
energy efficiency
η
s for the various models, as listed in the below table.