Assembly
Air/Exhaust Venting
Installation Options
Room air dependent
B23
Room air independent PPS/Alu white
C33x
C43x
Connection to AZ / LAS (2 conductor) multiple assignment
By customer
C53x
By customer
C63x
C83x
By customer
Exhaust connected to exhaust system
Multiple assignment (vacuum, overpressure)
Basement installation
Air supply from installation room
Exhaust venting via roof
Air and exhaust venting via roof at same pressure range
Basement installation
Exhaust and ventilation system to exhaust chimney
Air and exhaust venting via roof
Installation in moisture
-
resistant exhaust chimney
Air and exhaust venting via roof at same pressure range
Floor or roof installation
Exhaust and ventilation system via pitched or flat roof
Air supply and exhaust venting to outside in different pressure ranges
Air and exhaust connection to separate tested and supplied
air / exhaust pipes
Basement / floor installation
Air and exhaust venting via exterior wall
Exhaust venting through heat insulated exhaust pipe or AZ
-
AW
Exhaust line (standing air layer) at exterior wall
Exhaust connection to exhaust system, multiple assignment (vacuum)
Combustion air supply via separate air pipe.
11
Minimum shaft diameters
Shaft rear ventilation pursuant to DIN 18160
when using B23 configuration
(room air dependent)
Exhaust pipe
diameter
110
mm
> 168
188
en