![elco RENDAMAX 30 Operating Instructions Manual Download Page 6](http://html1.mh-extra.com/html/elco/rendamax-30/rendamax-30_operating-instructions-manual_2377077006.webp)
Product description
Circuit diagram
Compact gas fitting
Circuit diagram
The circuit diagram is integrated in the
burner with all the above operating
elements.
The system electronics KM628 offers:
-
Management for modulating boiler
regulator
-
Hot water preparation
Compact gas fitting
The compact gas fitting works as a gas
safety close valve and as regulator.
The regulator functions as a pneumatic
gas / air difference pressure regulator.
On the gas side, it controls the gas
pressure P
O
in the function of the
combustion air pressure P
L
.
If no air pressure is built up (P
L
= 0),
the gas valve remains closed. The gas/
air pressure ratio and thus also the gas
air volume ratio can be set and then/
remain almost constant over the set
load range.
Technical data
Safety close valve
2, class B/C
Mains power
Type
65-100
AC
24
V
Type
120 AC
230
V
Power consumption
Type
65-100
0,42
A
Type
120 0,09
A
Gas fitting incl. gas filter
1 Operating
type
i
Standby
q
Automatic
operation
F
Summer
operation
j
Chimney sweep operation
2
Operating type selector
3 Fault
display
E
4 Lead
temperature
5 Fault
code
(blinking)
6 Heating
circuit
status
C
Night
operation
B
Day
operation
(Blinking) Burner on
7 Service
status
j
I Service status minimum burner
output
j
II Service status maximum burner
output
5 6 7 4 3 2
1
6