turn the key left -  in order to unlock the function (the green light will 
appear, which means function has been engaged again).

 

When the thigh rest is fixed, the lower leg rest can be adjusted individually 

 there are two adjusting ratchets, which lock the lower leg rest into position. 

In order to raise the lower leg rest in the foot end up (without the mattress 
brackets) to the desired level 

 the lower leg automatically snap into place. 

In order to lower leg rest first it is necessary to lift the lower leg all the way 
to  the  stopping  point,  then  you  can  slowly  drop  the  lower  leg  rest  down.        
Also,  the  lower  leg  rest  will  be  dragged  down  automatically  if  you  lower                   
the thigh rest.  

Warning 

 

Do not put your fingers between moving parts of the mattress support 
platform 

 it can caused their entrapment and injuries! 

7.2. Side rails operating 

Warnings 

 

It  is  necessary  to  hold  side  rails  during  lowering  them  to  avoid  rapid 
decrease.  

 

The  ends  of  side  rails  shall  be  always  at  the  same  level  of  mattress 
support platform head section and foot section.   

 

Lowering height of mattress support platform with side rails in the lowest 
position or bringing side rails down if mattress support platform is in the 
lowest position, can cause foot entrapment!  

To raise wooden side rails pull them on an one end 

after the other until they lock in its highest position 

 

there  should  not  be  any  possibility  to  move  them  up                   
or down. 

To lower wooden side rails raise them slightly, push 

the locking button and lower them slowly 

 do not let 

to rapid decrease.  

7.3. Setting the springiness of mattress support 
platform 

Warning 

 

Rashness  can  caused  finger  entrapment  between  mattress  support 
platform and sliding cube. 

 The springiness for the individual  wooden slats can be adjusted using six 
slides  fixed  to  the  center  of  the  slatted  frame,  which    allows  to  adjust  it                  

to suit the patient’s weight within certain limits. 

 

 pull slide out (+) to outside bed direction -  increase hardness, 

 push slide in (-) to inside bed direction 

 decrease hardness. 

Summary of Contents for B 521 II

Page 1: ...INSTRUCTION FOR USE ELBUR Nursing Beds PB 521 II PB 526 II ELBUR PB 521 II ELBUR PB 526 II...

Page 2: ......

Page 3: ...ty of our products In order to meet customer expectations we provide wide range of bed height adjustment We also care about attractive design as well as matching furniture systems and accessories whic...

Page 4: ...es 11 2 3 1 General information 11 2 3 2 Electrical components information 12 2 3 3 Information for care personnel 12 2 3 4 Assembly information 13 2 3 5 Service information 13 3 0 Scope of delivery 1...

Page 5: ...6 12 Assembly of the lifting pole 21 7 0 Operating of the nursing bed 21 7 1 Electric mattress support adjustment 22 7 2 Side rails operating 23 7 3 Setting the springiness of mattress support platfor...

Page 6: ...rective 93 42 EEC concerning medical devices EN 60601 1 Medical electrical equipment Part 1 General requirements for basic safety and essential performance EN 60601 2 52 Medical electrical equipment P...

Page 7: ...20 Conditions operating storage Temperature o C 10 40 Humidity 30 75 Temperature o C 5 45 Humidity 30 75 Mattress Dimensions HxWxL 10x90x200 cm 12x90x200 cm Volume density of foamed material 35 50 kg...

Page 8: ...barcode max patient weight safe working load manufacturer information and warning symbols 1 3 2 Information labeling Max Patient Weight 140 kg for PB 521 II this value is 165 kg Safe Working Load 175...

Page 9: ...pplication part type B according to EN 60601 1 electrical appliance class II double insulated ingress protection of electrical parts from splashwater do not use the medical device outdoors product mus...

Page 10: ...any time It is necessary to contact physician in charge to make sure that there are not any limitations of use nursing bed in daily healthcare Due to the design ELBUR nursing beds are only approved f...

Page 11: ...in proper and faultless condition Only use technically perfect bed Contact manufacturer or distributor if the exchange or repair of faulty parts have to be made If damage or malfunction is suspected...

Page 12: ...cable is damaged that there is no loop in the cables and that they are not crushed by moving parts or components of other devices It is essential to leave the nursing bed unused for at least 18 minut...

Page 13: ...stomer service 2 3 4 Assembly information Warnings Read instruction carefully before commencing assembly Verify the shipment contents with your order before commencing assembly to make sure that you h...

Page 14: ...contact your distributor or Elbur customer service if you miss any component or get something in bad condition Scissor lift with drive unit Different models are available to order without castors on k...

Page 15: ...done by manufacturer 4 2 Back rest foot rest drive units Nursing beds described in this instruction manual have one drive unit used to adjust back rest section and one drive unit used to adjust upper...

Page 16: ...es and spare parts Warnings Use only original Elbur accessories and spare parts modification of nursing beds is strictly forbidden without authorization of our company It is necessary to perform speci...

Page 17: ...d boards out of the box bring all accessories side rails drive units and all other components out of the box remove all unnecessary package s items 6 3 Assembly of mattress support platform on the sci...

Page 18: ...pport platform scissor lift lugs then connect it using quick release bolts 6 4 Location of drive units and control box for mattress support platform Warning Take special care in assigning the drive un...

Page 19: ...n drive unit is fixed under mattress support platform with the motor housing towards the head end board label on the bed align holes in holders and the drive insert the quick release bolt and secure b...

Page 20: ...t functions ensure that the cables and wires cannot be damaged or overstretched The nursing bed should be plugged in to the separate socket during the tests There must be enough space for bed height a...

Page 21: ...t Warning Wrong assembly of the side rails does not let to achieve required distance from the top of the mattress to the top edge of the top side rail which can caused patient s entrapment or falling...

Page 22: ...adjustment range of height or angle of mattress support platform is possible only within a predetermined range The electrical adjustments can be made using the hand switch which functions are describ...

Page 23: ...rails during lowering them to avoid rapid decrease The ends of side rails shall be always at the same level of mattress support platform head section and foot section Lowering height of mattress suppo...

Page 24: ...different position follow safety rules indicated below mattress support platform has to be in flat and horizontal position side rails has to be latched and in upper position unplug the mains power cab...

Page 25: ...olt out of the hole in the mounting holder then first person can carefully lower the back rest to the flat position To convert the bed back to its normal operating state the quick release bolt has to...

Page 26: ...c components 4 Drive units Housings should be wiped only with a slightly moisturized cloth 9 0 Service Warnings Only specially authorized technicians are allowed to carry out troubleshooting activitie...

Page 27: ...t inspection Repeat inspection Inspection following repairs servicing Manufacturer s final inspection Electrical appliance class I II Manufacturer Elbur sp z o o sp k Bed type PB _____________________...

Page 28: ...ease bolts mounting drive units fitted properly YES NO Is lifting pole distorted YES NO Is triangle grab handle still good enough to use YES NO 1 2 Visual inspection of the electrical components Is th...

Page 29: ...re control and blocking functions of the hand switch working properly YES NO Are drive units working properly abnormal noises smooth operation YES NO 3 2 Performance check of the mechanical components...

Page 30: ...__________________________________________________________ ____________________________________________________________ Comments ____________________________________________________________ __________...

Page 31: ...after 30 minutes break from using adjustment functions Disabler in the hand control activated Deactivate disabler turn key to the left Hand control damaged Notify customer service Control box damaged...

Page 32: ...perfect condition Technical specifications subclause 1 2 contain guidance of operating and storage conditions for ELBUR nursing beds Nursing bed shall be protected from destruction under external infl...

Page 33: ...__________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ______...

Page 34: ...ELBUR PB 521 II PB 526 II Elbur sp z o o sp k 34 of 36...

Page 35: ......

Page 36: ...Elbur sp z o o sp k Dzia osza 34 56 500 Syc w POLAND Tel 48 62 786 97 80 e mail info elbur eu www elbur eu E TF 2E 13 01 02 11 2020...

Reviews: