Features  

GSM transmiter

Supports up to 10 remote controls, 99 wireless accessories and 50 RFID tags

 

Can store up to 5 phone numbers, 5 SMS numbers. 

a Central Monitoring System)

Arm / disarm the system by SMS, phone call, or App (on iOS or Android)

 

Can be disarmed by RFID tag

Built-in siren (110dB) 

Call function from the panel

SMS alerts for power failure, power recovery and low battery

Audio surveillance of the site from distance

2 x 800mAh lithium batteries included (8h battery life in standby mode)

Speci ications  

Product name

ST-SK1

SKU

ST-SK1

Control panel power supply

 

Input: AC 110-240V / 50-60 Hz

 

Output: DC 12V / 800 A

GSM working frequency

 

850 / 900 / 1800 / 1900 mHz

Radio-frequency

433.92MHz (±75KHz)

Transmission distance

80m in open space

Standby current

80ma

Alarm current

300mA

Backup batteries

Lithium Batteries: 3.7V / 800 mAh x 2 (BL-5B)

(8h battery life in standby mode)

Internal siren

95dB

Housing material

ABS plastic

Operating conditions

 

Temperature: -10°C~55°C

 

Humidity: ≤ 80% (non-condensing)

Control panel dimensions (L x W x H)

 

188 x 125 x 25 mm

Box content  

SS1 Control Panel x1

Moton Detectors x1

Door / Window Contacts x1

Remote Controls x2

RFID Tags x2

AC Adaptor x1

Documentation x1

Box content  

Call

Clear

RFID Reader

Home Mode

LCD Display

Disarm

Record

Arm

SOS

Control Panel Layout (Back) 

Power On/Off

Adapter interface

24h Zone

Electronic lock

Wired siren

GND

SPK

LOCK

Z1

+12V

GND

Monitoring MIC

Speaker

Power Supply Interface

Tamper Switch

Power Switch

Telephone Interface

Battery 

Compartment

SIM Card Slot

Summary of Contents for ST-SK1

Page 1: ...I N S T A L L A T I O N M A N U A L GSM Alarm Security System ST SK1...

Page 2: ...ency 850 900 1800 1900 mHz Radio frequency 433 92MHz 75KHz Transmission distance 80m in open space Standby current 80ma Alarm current 300mA Backup batteries Lithium Batteries 3 7V 800 mAh x 2 BL 5B 8h...

Page 3: ...panel on the wall make sure the reception of the GSM signal is sufficient Fix the wall mounting bracket on the wall with screws Wedge the panel on the bracket make sure they fit well Basic Operations...

Page 4: ...necessary to set up your system 123456 User code necessary to disarm your system or stop the alarm 1234 Duress code 0000 enables you to trigger a duress alarm Open door code 8888 enables you to open a...

Page 5: ...added the countdown starts over from 30 so that you can register another RFID tag in control panel up to 50 tags can be registered in the control panel Press Esc to exit Delete all 1 YES 0 NO Delete...

Page 6: ...tem Setting Control by Phone ON or OFF You can activate or deactivate the control of your system by phone call Activating the control by phone call enables you to arm and disarm the system and monitor...

Page 7: ...silently Default setting On Wireless Siren Siren Switch ON OFF Enable Disable the siren Default setting On Wireless siren refers to a siren connect ed to the control panel by radio fre quency Arm Disa...

Page 8: ...nly after having enabled it from the control panel as explained on page 10 of this manual Method 1 When an alarm has been triggered the control panel dials the stored phone numbers When you pick up th...

Page 9: ...he control panel The speech bubbles that follow are the dialogue between the user and the control panel SMS sent by the user are in blue SMS sent by the control panel are in grey The system is in Engl...

Page 10: ...e Zones names 1 Entrance door sensor Ok Note Zones 1 to 9 can be renamed The name of the zone cannot consist of more than 30 Latn characters Zones 10 to 99 cannot be renamed SMSAlertforAccessoryLowBat...

Page 11: ...ste then edit case sensitive Ok Note Thisfunction can be used if you do not want to bring a remote control or a RFID tag with you When you arm the system the system will be armed after the delay set W...

Page 12: ...OS Disarm LED indicator Arm the system Press the Arm button to arm the alarm system The LED indicator lights up the control panel beeps once The system is armed If an intruder is detected the siren ri...

Page 13: ...ea Radio frequency 433MHz 75KHz Housing material ABS plastic Operating conditions Temperature 10 C 55 C Relative Humidity 80 non condensing Dimensions 57 x 31 x 11 mm Design 3 1 2 1 LED indicator 2 De...

Page 14: ...s Fix the bracket on the wall with screws and attach the detector to the bracket Adjust the bracket to change the detection distance and angle It is recommended to mount the detector 2 2 m from the gr...

Page 15: ...rol panel To check if the registration is complete arm the system and separate the magnet from the transmitter again by opening the door or window on which it is installed If the siren rings out the r...

Page 16: ...When attempting the connection the control panel beeps twice The accessory has already been connected Make sure you do not trigger any other accessory when connecting one accessory to the control pan...

Page 17: ...one by professional personnel only Standards This product bears the selective sorting symbol for waste electrical and electronic equipment WEEE This means that this product must be handled pursuant to...

Page 18: ...ELBRO AG Gewerbestrasse 4 CH 8162 Steinmaur Switzerland www elbro com...

Reviews: