Change System Language 

Send the code corresponding to the 

language you want to set. For example, 

for English, send “

0001

”.  

0001

Ok

Refer to the table below for the full list of 

languages:

0001 English

0002 French

0003 German

0004  Italian

Languages available may vary depending on 

the version of your product.

Restore System to Factory Settings by SMS 

Send:

Ok

The settings will be restored to default values. 

Stored phone numbers and connected 

accessories will not be deleted.

Note

Only stored numbers can send the SMS to 

restore factory settings.

Accessories

Wireless Remote Control 

Home Mode

Arm

SOS

Disarm

LED indicator

Arm the system 

Press the Arm button

 

 "

 

" to arm the alarm 

system.  The  LED  indicator  lights  up  (the 

control  panel  beeps  once).  The  system  is 

armed.
If an intruder is detected, the siren rings out. 

(The  siren  turns  off  after  5  minutes  as  per 

default settings.) In the meantime, the system 

dials the stored phone numbers automatically.

Disarm the system

Press the Disarm button

 

 "

   

" to disarm the 

alarm system. The LED indicator turns off (the 

control  panel  beeps  twice).  The  system  is 

disarmed.

Home Mode

Press  the  Home  Mode  button  " " on the 

remote control. The system state LED is on. 

All the sensors in regular zones are armed 

except those in the Home Mode zone. 

The sensors in the Home Mode zone are 

disarmed so that users can move inside their 

home.

0000

Summary of Contents for ST-SK1

Page 1: ...I N S T A L L A T I O N M A N U A L GSM Alarm Security System ST SK1...

Page 2: ...ency 850 900 1800 1900 mHz Radio frequency 433 92MHz 75KHz Transmission distance 80m in open space Standby current 80ma Alarm current 300mA Backup batteries Lithium Batteries 3 7V 800 mAh x 2 BL 5B 8h...

Page 3: ...panel on the wall make sure the reception of the GSM signal is sufficient Fix the wall mounting bracket on the wall with screws Wedge the panel on the bracket make sure they fit well Basic Operations...

Page 4: ...necessary to set up your system 123456 User code necessary to disarm your system or stop the alarm 1234 Duress code 0000 enables you to trigger a duress alarm Open door code 8888 enables you to open a...

Page 5: ...added the countdown starts over from 30 so that you can register another RFID tag in control panel up to 50 tags can be registered in the control panel Press Esc to exit Delete all 1 YES 0 NO Delete...

Page 6: ...tem Setting Control by Phone ON or OFF You can activate or deactivate the control of your system by phone call Activating the control by phone call enables you to arm and disarm the system and monitor...

Page 7: ...silently Default setting On Wireless Siren Siren Switch ON OFF Enable Disable the siren Default setting On Wireless siren refers to a siren connect ed to the control panel by radio fre quency Arm Disa...

Page 8: ...nly after having enabled it from the control panel as explained on page 10 of this manual Method 1 When an alarm has been triggered the control panel dials the stored phone numbers When you pick up th...

Page 9: ...he control panel The speech bubbles that follow are the dialogue between the user and the control panel SMS sent by the user are in blue SMS sent by the control panel are in grey The system is in Engl...

Page 10: ...e Zones names 1 Entrance door sensor Ok Note Zones 1 to 9 can be renamed The name of the zone cannot consist of more than 30 Latn characters Zones 10 to 99 cannot be renamed SMSAlertforAccessoryLowBat...

Page 11: ...ste then edit case sensitive Ok Note Thisfunction can be used if you do not want to bring a remote control or a RFID tag with you When you arm the system the system will be armed after the delay set W...

Page 12: ...OS Disarm LED indicator Arm the system Press the Arm button to arm the alarm system The LED indicator lights up the control panel beeps once The system is armed If an intruder is detected the siren ri...

Page 13: ...ea Radio frequency 433MHz 75KHz Housing material ABS plastic Operating conditions Temperature 10 C 55 C Relative Humidity 80 non condensing Dimensions 57 x 31 x 11 mm Design 3 1 2 1 LED indicator 2 De...

Page 14: ...s Fix the bracket on the wall with screws and attach the detector to the bracket Adjust the bracket to change the detection distance and angle It is recommended to mount the detector 2 2 m from the gr...

Page 15: ...rol panel To check if the registration is complete arm the system and separate the magnet from the transmitter again by opening the door or window on which it is installed If the siren rings out the r...

Page 16: ...When attempting the connection the control panel beeps twice The accessory has already been connected Make sure you do not trigger any other accessory when connecting one accessory to the control pan...

Page 17: ...one by professional personnel only Standards This product bears the selective sorting symbol for waste electrical and electronic equipment WEEE This means that this product must be handled pursuant to...

Page 18: ...ELBRO AG Gewerbestrasse 4 CH 8162 Steinmaur Switzerland www elbro com...

Reviews: