ELBRO ST-SK1 Installation Manual Download Page 15

29

28

Wireless Door / Window Contact 

Features

This Door / Window Contact can be installed on doors, windows, and any other objects that 

open and close. The sensor sends a signal to the control panel when the magnet is separated 

from the transmitter.

Thanks to the tamper switch, any attempt to remove the cover of the Door / Window Contact 

will trigger the alarm.

Design

Magnet

Transmitter

LED indicator

PCB Layout

LED working indicator

Zone setting

A23 12V battery

Tamper switch

LED indications

Blinks once: the door or window is open and the transmitter sends a signal to the control panel.

Blinks quickly: Low power indication, the batteries must be replaced.

Register in the control panel

Navigate through the menu of the control panel and reach "

ADD A NEW

" (Wireless Sensor). 

Then separate the magnet from the transmitter to register the detector in the control panel.

To  check  if  the  registration  is  complete,  arm  the  system  and  separate  the  magnet  from  the 

transmitter again by opening the door or window on which it is installed. If the siren rings out, 
the registration is successful. 

Installation

Open the case and remove the battery activation strip.

Mount the sensor on the door and the magnet on the 

door frame.

Make sure the magnet is placed above the transmitter.

Mount the magnet max. 1 cm away from the transmitter 

and secure the transmitter and magnet with double-sided 

tape or screws.

Avoid mounting the sensor in areas with a large amount of 

metal or electrical wiring such as a furnace or utility room.

Specifications

Power supply

DC 12V (A23 12V Battery x 1)

Static current

≤ 30 uA

Alarm current

≤ 15 mA

Transmitting distance

≤80 m (in open area)

Radio-frequency

433 MHz (±75 KHz)

Housing material

ABS plastic

Operating conditions

Temparature: -10°C~55°C

Relative humidity: ≤ 80% (non-condensing)

Transmitter dimensions (LxWxH)

 

60 x 45 x 18 mm

Magnet dimensions (LxWxH)

 

45 x 19 x 17.5 mm

Summary of Contents for ST-SK1

Page 1: ...I N S T A L L A T I O N M A N U A L GSM Alarm Security System ST SK1...

Page 2: ...ency 850 900 1800 1900 mHz Radio frequency 433 92MHz 75KHz Transmission distance 80m in open space Standby current 80ma Alarm current 300mA Backup batteries Lithium Batteries 3 7V 800 mAh x 2 BL 5B 8h...

Page 3: ...panel on the wall make sure the reception of the GSM signal is sufficient Fix the wall mounting bracket on the wall with screws Wedge the panel on the bracket make sure they fit well Basic Operations...

Page 4: ...necessary to set up your system 123456 User code necessary to disarm your system or stop the alarm 1234 Duress code 0000 enables you to trigger a duress alarm Open door code 8888 enables you to open a...

Page 5: ...added the countdown starts over from 30 so that you can register another RFID tag in control panel up to 50 tags can be registered in the control panel Press Esc to exit Delete all 1 YES 0 NO Delete...

Page 6: ...tem Setting Control by Phone ON or OFF You can activate or deactivate the control of your system by phone call Activating the control by phone call enables you to arm and disarm the system and monitor...

Page 7: ...silently Default setting On Wireless Siren Siren Switch ON OFF Enable Disable the siren Default setting On Wireless siren refers to a siren connect ed to the control panel by radio fre quency Arm Disa...

Page 8: ...nly after having enabled it from the control panel as explained on page 10 of this manual Method 1 When an alarm has been triggered the control panel dials the stored phone numbers When you pick up th...

Page 9: ...he control panel The speech bubbles that follow are the dialogue between the user and the control panel SMS sent by the user are in blue SMS sent by the control panel are in grey The system is in Engl...

Page 10: ...e Zones names 1 Entrance door sensor Ok Note Zones 1 to 9 can be renamed The name of the zone cannot consist of more than 30 Latn characters Zones 10 to 99 cannot be renamed SMSAlertforAccessoryLowBat...

Page 11: ...ste then edit case sensitive Ok Note Thisfunction can be used if you do not want to bring a remote control or a RFID tag with you When you arm the system the system will be armed after the delay set W...

Page 12: ...OS Disarm LED indicator Arm the system Press the Arm button to arm the alarm system The LED indicator lights up the control panel beeps once The system is armed If an intruder is detected the siren ri...

Page 13: ...ea Radio frequency 433MHz 75KHz Housing material ABS plastic Operating conditions Temperature 10 C 55 C Relative Humidity 80 non condensing Dimensions 57 x 31 x 11 mm Design 3 1 2 1 LED indicator 2 De...

Page 14: ...s Fix the bracket on the wall with screws and attach the detector to the bracket Adjust the bracket to change the detection distance and angle It is recommended to mount the detector 2 2 m from the gr...

Page 15: ...rol panel To check if the registration is complete arm the system and separate the magnet from the transmitter again by opening the door or window on which it is installed If the siren rings out the r...

Page 16: ...When attempting the connection the control panel beeps twice The accessory has already been connected Make sure you do not trigger any other accessory when connecting one accessory to the control pan...

Page 17: ...one by professional personnel only Standards This product bears the selective sorting symbol for waste electrical and electronic equipment WEEE This means that this product must be handled pursuant to...

Page 18: ...ELBRO AG Gewerbestrasse 4 CH 8162 Steinmaur Switzerland www elbro com...

Reviews: