RFID Tag 

Features

The RFID tag enables you to disarm your system or unlock electronic door locks.

Register in the control panel

Refer to the instructions in the table page 8 of this manual (“

RFID TAG

”). 

Specifications

Dimensions

45 x 30 x 7 mm

Troubleshooting and maintenance

FAQ 

Issue

Cause of malfunction

Solution

No response following 

interaction with the 

control panel

The control panel is switched off

Open the battery compartment and 

turn the power on

Electricity grid failure

Contact your electricity provider

Backup batteries are empty

Plug the AC adapter to an AC socket

Accessories cannot 

connect to the control 

panel

The control panel is not in 

Connection mode

Make sure the control panel is in 

Connexion mode

Accessories have not been 

triggered for connection

Make sure the accessory is triggered so 

to send a signal to the control panel

When attempting the 

connection, the control panel 

beeps twice

The accessory has already been 

connected

Make sure you do not trigger any 

other accessory when connecting one 

accessory to the control panel (e.g. do 

not stay in the detection scope of a 

motion detector if it is not the one you 

want to connect)

No response from the 

control panel following 

commands from the 

remote control

The remote control has not been 

connected to the control panel

Follow the instructions in this manual 

to connect the remote control to the 

panel

Remote control is too far from 

the control panel

Transmission distance of the remote 

control: 80 m (in open area)

A signal repeater can be installed to 

increase the transmission distance

RFID tag fails to disarm 

the system

RFID tag has not been connected 

to the control panel

Follow the instructions in this manual 

to connect the RFID tag to the control 

panel

Impossible to access 

settings from the control 

panel

You are not in the setup menu of 

the LCD display

Enter your admin code followed 

by “

Enter

“ to enter the setup 

menu

Summary of Contents for ST-SK1

Page 1: ...I N S T A L L A T I O N M A N U A L GSM Alarm Security System ST SK1...

Page 2: ...ency 850 900 1800 1900 mHz Radio frequency 433 92MHz 75KHz Transmission distance 80m in open space Standby current 80ma Alarm current 300mA Backup batteries Lithium Batteries 3 7V 800 mAh x 2 BL 5B 8h...

Page 3: ...panel on the wall make sure the reception of the GSM signal is sufficient Fix the wall mounting bracket on the wall with screws Wedge the panel on the bracket make sure they fit well Basic Operations...

Page 4: ...necessary to set up your system 123456 User code necessary to disarm your system or stop the alarm 1234 Duress code 0000 enables you to trigger a duress alarm Open door code 8888 enables you to open a...

Page 5: ...added the countdown starts over from 30 so that you can register another RFID tag in control panel up to 50 tags can be registered in the control panel Press Esc to exit Delete all 1 YES 0 NO Delete...

Page 6: ...tem Setting Control by Phone ON or OFF You can activate or deactivate the control of your system by phone call Activating the control by phone call enables you to arm and disarm the system and monitor...

Page 7: ...silently Default setting On Wireless Siren Siren Switch ON OFF Enable Disable the siren Default setting On Wireless siren refers to a siren connect ed to the control panel by radio fre quency Arm Disa...

Page 8: ...nly after having enabled it from the control panel as explained on page 10 of this manual Method 1 When an alarm has been triggered the control panel dials the stored phone numbers When you pick up th...

Page 9: ...he control panel The speech bubbles that follow are the dialogue between the user and the control panel SMS sent by the user are in blue SMS sent by the control panel are in grey The system is in Engl...

Page 10: ...e Zones names 1 Entrance door sensor Ok Note Zones 1 to 9 can be renamed The name of the zone cannot consist of more than 30 Latn characters Zones 10 to 99 cannot be renamed SMSAlertforAccessoryLowBat...

Page 11: ...ste then edit case sensitive Ok Note Thisfunction can be used if you do not want to bring a remote control or a RFID tag with you When you arm the system the system will be armed after the delay set W...

Page 12: ...OS Disarm LED indicator Arm the system Press the Arm button to arm the alarm system The LED indicator lights up the control panel beeps once The system is armed If an intruder is detected the siren ri...

Page 13: ...ea Radio frequency 433MHz 75KHz Housing material ABS plastic Operating conditions Temperature 10 C 55 C Relative Humidity 80 non condensing Dimensions 57 x 31 x 11 mm Design 3 1 2 1 LED indicator 2 De...

Page 14: ...s Fix the bracket on the wall with screws and attach the detector to the bracket Adjust the bracket to change the detection distance and angle It is recommended to mount the detector 2 2 m from the gr...

Page 15: ...rol panel To check if the registration is complete arm the system and separate the magnet from the transmitter again by opening the door or window on which it is installed If the siren rings out the r...

Page 16: ...When attempting the connection the control panel beeps twice The accessory has already been connected Make sure you do not trigger any other accessory when connecting one accessory to the control pan...

Page 17: ...one by professional personnel only Standards This product bears the selective sorting symbol for waste electrical and electronic equipment WEEE This means that this product must be handled pursuant to...

Page 18: ...ELBRO AG Gewerbestrasse 4 CH 8162 Steinmaur Switzerland www elbro com...

Reviews: