5. PREPARATION AND INSTALLATION ELBO CONTROLLI srl
Preset E236+
14
ý
Connection Procedure
•
Connect the Presetter to the earthing terminal, using the yellow/green minimum sect. 1,5 mmq, fix it to
the appropriate clamp.
•
Connect the eventual label printer
s’Print-S
to the serial port RS-232 (see para. 5.7.3)
•
Connect the feeder of the E236+ inserting the round spine of the power supply into the presetter’s feeder
socket.
•
Assemble the suitable adaptor into the feeder supply socket and insert the plug into the mains electricity
115/230V AC, 50/60Hz.
5.7.1 USB PORT
The USB port on the rear panel of the instrument can be used to connect to a personal
computer with a Windows
Ò
operating system, the TD236+ software provided with the
presetter can be installed.
5.7.2 SERIAL PORT RS-232
The serial port found on the rear panel of the instrument can be used to connect the label printer
s’Print-S
(optional).
The connection is made with a standard D-type 9 male connectors, having the following configuration:
•
pin 2: Rx
•
pin 3: Tx
•
pin 5: GND
The communication parameters of the serial port are:
•
19200 Baud
•
8 data bits
•
1 o 2 stop bit
•
no parity
•
no handshake
5.7.3 CONNECTING THE LABEL PRINTER
s’Print-S
The
s’Print-S
label printer can be connected through the serial port present on the connection panel of the
E236+ observing the following procedures:
ý
Connection procedures and using the label printer
s’Print-S
The printer
s’Print-S
is embedded in the factory to function exclusively with the labels included in the
packing.
The pace of printing between one label and the next is automatically understood thanks to the optic sensor
that marks in black individually (signposts) those present on the roll.
For this reason, it isn’t possible to use the normal roll of labels or thermal paper without modifying the
predefined settings.