Power Spot 575™
©Elation Professionals® Los Angeles, Ca. - wwww.ElationLighting.com - Page
25
DMX Address
D001
D001
Pan reverse
RPAN
ON
OFF
Tilt reverse
RTLT
ON
OFF
Automatic lamp on
LAAU
ON
OFF
Lamp on via DMX
DLOF
ON
OFF
Display
DISP
D ON
Cooling fan
FANS
HIGH
REG
LOOF
LOHI
Feedback
FEED
ON
OFF
3.9.10 Feedback
”APC”
FEED
The POWER SPOT 575™ is equipped with
”APC,”
automatic position
correction. This function automatically corrects the Pan and Tilt movement
should the unit lose step or is obstructed and forced to lose step. Press the
Enter
button to access the sub-menu. Use the
Up
and
Down
buttons to toggle
between “ON” and “OFF” and confirm once more with the
Enter
button or use
the
Mode
button to cancel the operation.
3.9.11 Error and Fault Corrections
EFLG
(These functions are reserved for authorized technicians only)
3.10 Error and Information Messages
HEAt
This message appears if you try to switch on the lamp within 5
minutes after having switched off (lamp too hot). The message
will appear on the display if the lamp doesn’t ignite within 20
seconds. The fixture will store this command and automatically
ignite the lamp after 5 minutes.
LaeR
After the ignition of the lamp was two times not successful the
display will show
LAER
. That means the lamp could be damaged
or even missed, the fixture is overheating or there could be a
failure on the igniter or ballast. Switch off the power supply and