1. Have Z-Wave

TM

 Controller entered association 

mode.

2. Pressing tamper key three times within 1.5 seconds

will enter association mode.

Note: The device support 2 groups. The group 1 is for 

receiving the report message, like triggered event, 

temperature, illumination etc. The group 2 is for light 

control, the device will send the “Basic Set” command 

to this group.

Including a node ID allocated by Z-Wave

TM

 Controller means 

inclusion.  Excluding a node ID allocated by Z-Wave

TM

  

Controller means exclusion.

Failed or success in including/excluding the node ID can be 

viewed from Z-Wave

TM

 Controller.

Notice 1:

 Always RESET a Z-Wave

TM

 device before trying to add it to a 

Z-Wave

TM

 network. 

Notice 2:

 When the device into NWI mode, any tamper key and 

sensor functionality will useless. The NWI will timeout after 30 seconds.

Z-Wave

TM

 Notification

After the device adding to the network, it will wake-up once per day in

default. When it wake-up it will broadcast the “Wake Up Notification”

message   to   the   network,   and   wake-up   10   seconds   for   receive   the

setting commands.

The wake-up interval minimum setting is 30 minutes, and maximum

setting is 120 hours. And the interval step is 30 minutes.

If the user want to wake-up the device immediately, please remove the

front cover, and press the tamper key once. The device will wake-up 10

seconds.

Z-Wave

TM

 Message Report

* Motion Report:

When the PIR motion detected, the device will unsolicited to send the

“Sensor Binary Report” to the nodes in the group 1.

Sensor Type: Motion (0x0C)

Sensor Value: 0xFF

* Tamper Report:

When the 2 tamper keys in the device are pressed over 5 seconds. The

device will into the alarm state. In that state, if any one of the tamper

keys be released, the device will unsolicited to send the “Sensor Binary

Report” to the nodes in the group 1.

Sensor Type: Tamper (0x08)

Sensor Value: 0xFF

* Temperature Report:

When the PIR motion detected, the device will unsolicited to send the

“Sensor Multilevel Report” to the nodes in the group 1.

Sensor Type: Temperature (0x01)

Note: To disable this functionality by setting the configuration setting

N0.5, the bit5 of the value to 1.

*** Temperature differential report ***

This function default is disabled, to enable by setting the configuration

setting NO.6 bit6 to 1.

When the temperature plus or minus three degree Fahrenheit (1.67

degree Celsius), the device will report temperature information to the

nodes in the group 1. 

The device will measure the temperature in every 64 seconds. And if

the temperature is over 140 degree Fahrenheit (60 degree Celsius), the

device also report in each measurement. 

* Illumination Report:

When the PIR motion detected, the device will unsolicited to send the

w w w . e k t

2

. c o m

Electronics 

Katrangi

 Trading

Summary of Contents for TSP01

Page 1: ...f them can inclusion exclusion reset or association from Z WaveTM network In the first time add the device into the Z WaveTM network First make sure the primary controller is in the inclusion mode And then power on the device just take out the insulation Mylar in the back side of the device The device will auto start the NWI Network Wide Inclusion mode And it should be included in 5 seconds You wi...

Page 2: ...ront cover and press the tamper key once The device will wake up 10 seconds Z WaveTM Message Report Motion Report When the PIR motion detected the device will unsolicited to send the Sensor Binary Report to the nodes in the group 1 Sensor Type Motion 0x0C Sensor Value 0xFF Tamper Report When the 2 tamper keys in the device are pressed over 5 seconds The device will into the alarm state In that sta...

Page 3: ... on the device will check is it already adding to the network If doesn t it will auto start the NWI mode The LED will flash in every second and continue 30 seconds Until timeout or the device successful to inclusion by controller Wake When the power on the device will wake about 20 seconds In this duration the controller can communicate with the device Normally the device is always sleeping to sav...

Page 4: ...ion setting NO 4 the device will emit the signal to turn ON the lighting equipment those nodes in the group 2 And delay a while to turn OFF the lighting equipment The delay time is setting by the configuration setting NO 9 The PIR motion re detected interval in the Test Mode fixed to 6 seconds In the Home Automation Mode will start detect before turn OFF the lighting equipment In the Security Mode...

Page 5: ... the front cover and pull back 3 Hold the front cover and pull up Replace the new battery and install the cover back 1 Put the front cover bottom to 1 1 and press down 2 Push the front cover top to 2 1 Choosing a Suitable Location 1 The recommended mounting height is 160cm 2 Don t let the device facing the window or the sunlight 3 Don t let the device facing the source of heat Like heater w w w e ...

Page 6: ...o as A tape and another is thinner hereinafter referred to as B tape you can use A tape for the test at the beginning The right way for A tape installation is stick it to the position below tamper key The thicker tape won t let the tamper key close so the sensor will enter the test mode You may test if installed position is good or not by this way After finish the test and decide to fix then you c...

Page 7: ...est mode Notice Bit0 and bit1 will effect when the DIP Switch setting to program mode If bit1 is enabled the bit0 is useless Bit2 Reserved always 1 Bit3 Setting the temperature scale 0 Fahrenheit 1 Celsius Bit4 Disable illumination report after event triggered Bit5 Disable temperature report after event triggered 6 Multi Sensor Function Switch 4 0 127 Multi Sensor function switch Using bit to cont...

Page 8: ...ture Time 12 1 127 The interval time for auto report the temperature 30 minutes per tick and minimum time is 30 minutes default tick is 12 6 hours Z Wave Supported Command Class COMMAND_CLASS_CONFIGURATION COMMAND_CLASS_VERSION COMMAND_CLASS_SENSOR_BINARY_V2 COMMAND_CLASS_ASSOCIATION_V2 COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 COMMAND_CLASS_WAKE_UP_V2 COMMAND_CLASS_SENSOR_MULTILEVEL_V5 COMMAND_CLASS...