background image

The slim multi-sensor TSP01 has PIR, temperature and illumination, 3

sensors function in one, based on Z-Wave

TM

 technology.  Z-Wave

TM

 is a

wireless   communication   protocol   designed   for   home   automation,

specifically   to   remotely   control   applications   in   residential   and   light

commercial environments. The technology uses a low-power RF radio

embedded or retrofitted into home electronics devices and systems,

such   as   lighting,   home   access   control,   entertainment   systems   and

household appliances.

This device is one component of the Z-Wave

TM

  sensor system and is

designed to work with all other Z-Wave

TM

  enabled devices in a home

control network. The device adopt the Z-Wave

TM

 400 series chip, when

your   Z-Wave

TM

  network   system   is   all   made   by   Z-Wave

TM

  400   series

devices. The network system will have the advantages as below.

Concurrent multi-channel support reduces external interference.

Better RF range, improve about 10 meters in indoor.

Support 100 Kbps transmit speed, speed up communication.

Adding to Z-Wave

TM

 Network

There are two  tamper keys in  the device, one  is in the back  side,

another is in the front side. They have the same function. Both of them

can inclusion, exclusion, reset or association from Z-Wave

TM

 network.

In the first time, add the device into the Z-Wave

TM

 network.  First, make

sure the primary controller is in the inclusion mode. And then power on

the device, just take out the insulation Mylar in the back side of the 

device. The device will auto start the NWI (Network Wide Inclusion) 

mode. And it should be included in 5 seconds. You will see the LED 

light ON one second.

Function

Description

Inclusion

1. Have Z-Wave

TM

 Controller entered inclusion mode.

2. Pressing tamper key three times within 1.5 seconds

will enter inclusion mode.

3. After inclusion successful, the device will wake to 

receive the setting command from Z-Wave

TM

 

Controller about 20 seconds.

Exclusion

1. Have Z-Wave

TM

 Controller entered exclusion mode.

2. Pressing tamper key three times within 1.5 seconds

will enter exclusion mode.

Node ID has been excluded.

Reset

1. Pressing tamper key four times within 1.5 seconds 

and do not release the tamper key in the 4

th

 

pressed, and the LED will turn ON.

2. After 3 seconds the LED will turn OFF, after that 

within 2 seconds, release the tamper key. If 

successful, the LED will light ON one second. 

Otherwise, the LED will flash once.

3. IDs are excluded and all settings will reset to 

factory default.

w w w . e k t

2

. c o m

Electronics 

Katrangi

 Trading

Z-WAVE TSP01

User Manual

Summary of Contents for TSP01

Page 1: ...f them can inclusion exclusion reset or association from Z WaveTM network In the first time add the device into the Z WaveTM network First make sure the primary controller is in the inclusion mode And then power on the device just take out the insulation Mylar in the back side of the device The device will auto start the NWI Network Wide Inclusion mode And it should be included in 5 seconds You wi...

Page 2: ...ront cover and press the tamper key once The device will wake up 10 seconds Z WaveTM Message Report Motion Report When the PIR motion detected the device will unsolicited to send the Sensor Binary Report to the nodes in the group 1 Sensor Type Motion 0x0C Sensor Value 0xFF Tamper Report When the 2 tamper keys in the device are pressed over 5 seconds The device will into the alarm state In that sta...

Page 3: ... on the device will check is it already adding to the network If doesn t it will auto start the NWI mode The LED will flash in every second and continue 30 seconds Until timeout or the device successful to inclusion by controller Wake When the power on the device will wake about 20 seconds In this duration the controller can communicate with the device Normally the device is always sleeping to sav...

Page 4: ...ion setting NO 4 the device will emit the signal to turn ON the lighting equipment those nodes in the group 2 And delay a while to turn OFF the lighting equipment The delay time is setting by the configuration setting NO 9 The PIR motion re detected interval in the Test Mode fixed to 6 seconds In the Home Automation Mode will start detect before turn OFF the lighting equipment In the Security Mode...

Page 5: ... the front cover and pull back 3 Hold the front cover and pull up Replace the new battery and install the cover back 1 Put the front cover bottom to 1 1 and press down 2 Push the front cover top to 2 1 Choosing a Suitable Location 1 The recommended mounting height is 160cm 2 Don t let the device facing the window or the sunlight 3 Don t let the device facing the source of heat Like heater w w w e ...

Page 6: ...o as A tape and another is thinner hereinafter referred to as B tape you can use A tape for the test at the beginning The right way for A tape installation is stick it to the position below tamper key The thicker tape won t let the tamper key close so the sensor will enter the test mode You may test if installed position is good or not by this way After finish the test and decide to fix then you c...

Page 7: ...est mode Notice Bit0 and bit1 will effect when the DIP Switch setting to program mode If bit1 is enabled the bit0 is useless Bit2 Reserved always 1 Bit3 Setting the temperature scale 0 Fahrenheit 1 Celsius Bit4 Disable illumination report after event triggered Bit5 Disable temperature report after event triggered 6 Multi Sensor Function Switch 4 0 127 Multi Sensor function switch Using bit to cont...

Page 8: ...ture Time 12 1 127 The interval time for auto report the temperature 30 minutes per tick and minimum time is 30 minutes default tick is 12 6 hours Z Wave Supported Command Class COMMAND_CLASS_CONFIGURATION COMMAND_CLASS_VERSION COMMAND_CLASS_SENSOR_BINARY_V2 COMMAND_CLASS_ASSOCIATION_V2 COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 COMMAND_CLASS_WAKE_UP_V2 COMMAND_CLASS_SENSOR_MULTILEVEL_V5 COMMAND_CLASS...

Reviews: