1 to 100 means the light strength.

3 PIR Sensitivity

70

0~99

PIR sensitivity settings.
0 means disable the PIR motion.
1 means the lowest sensitivity,
99 means the highest sensitivity.
High sensitivity means can detected long
distance, but if there is more noise signal
in the environment, it will re-trigger too 
frequency. 

4 Light 

Threshold

99

0~100

Setting the illumination threshold to turn 
on the light. When the event triggered 
and the environment illumination lower 
then the threshold, the device will turn 
on the light.
0 means turn off illumination detected 
function. And never turn on the light.
1 means darkest.
99 means brightest.
100 means turn off illumination detected
function. And always turn on the light.

Notice:

 In none test mode, only the 

value in 1 to 99 will enable the 
illumination detected function and 
update the illumination value.

5 Operation 

Mode

0

0~127 Operation mode. Using bit to control.

Bit0: 1 means security mode, 
        0 means home automation mode.
Bit1: 1 means enable test mode, 
        0 means disable test mode.

Notice: 

Bit0 and bit1 will effect when the DIP 
Switch setting to program mode.
If bit1 is enabled, the bit0 is useless.

Bit2: Reserved, always 1.
Bit3: Setting the temperature scale.
  0: 

Fahrenheit

, 1:

Celsius

Bit4: Disable illumination report after 
event triggered.
Bit5: Disable temperature report after 
event triggered.

6

Multi-Sensor 

Function 

Switch

4

0~127

Multi-Sensor function switch. Using bit to
control.
Bit0: Reserved, always 1.
Bit1: Disable PIR integrate Illumination.
Bit2: Reserved, always 1.
Bit3: Reserved.
Bit4: Reserved.
Bit5: Reserved.
Bit6:Enable temperature monitoring.
When this bit enable, the temperature 
changed 3 degree Fahrenheit, it will 
report.
And also the temperature over 140 
degree Fahrenheit, it will report every 64
seconds.

8 PIR Re-Detect 

Interval Time

3

3~127 In the security mode, after the PIR 

motion detected, setting the re-detect 
time. 8 seconds per tick, and minimum 
time is 24 seconds, default tick is 3 (24 
seconds).
Setting the suitable value to prevent 
received the trigger signal too frequency.
Also can save the battery energy.

Notice:

 If this value bigger than the 

configuration setting

 

NO. 9. There is a 

period after the light turned off and the 

w w w . e k t

2

. c o m

Electronics 

Katrangi

 Trading

Summary of Contents for TSP01

Page 1: ...f them can inclusion exclusion reset or association from Z WaveTM network In the first time add the device into the Z WaveTM network First make sure the primary controller is in the inclusion mode And then power on the device just take out the insulation Mylar in the back side of the device The device will auto start the NWI Network Wide Inclusion mode And it should be included in 5 seconds You wi...

Page 2: ...ront cover and press the tamper key once The device will wake up 10 seconds Z WaveTM Message Report Motion Report When the PIR motion detected the device will unsolicited to send the Sensor Binary Report to the nodes in the group 1 Sensor Type Motion 0x0C Sensor Value 0xFF Tamper Report When the 2 tamper keys in the device are pressed over 5 seconds The device will into the alarm state In that sta...

Page 3: ... on the device will check is it already adding to the network If doesn t it will auto start the NWI mode The LED will flash in every second and continue 30 seconds Until timeout or the device successful to inclusion by controller Wake When the power on the device will wake about 20 seconds In this duration the controller can communicate with the device Normally the device is always sleeping to sav...

Page 4: ...ion setting NO 4 the device will emit the signal to turn ON the lighting equipment those nodes in the group 2 And delay a while to turn OFF the lighting equipment The delay time is setting by the configuration setting NO 9 The PIR motion re detected interval in the Test Mode fixed to 6 seconds In the Home Automation Mode will start detect before turn OFF the lighting equipment In the Security Mode...

Page 5: ... the front cover and pull back 3 Hold the front cover and pull up Replace the new battery and install the cover back 1 Put the front cover bottom to 1 1 and press down 2 Push the front cover top to 2 1 Choosing a Suitable Location 1 The recommended mounting height is 160cm 2 Don t let the device facing the window or the sunlight 3 Don t let the device facing the source of heat Like heater w w w e ...

Page 6: ...o as A tape and another is thinner hereinafter referred to as B tape you can use A tape for the test at the beginning The right way for A tape installation is stick it to the position below tamper key The thicker tape won t let the tamper key close so the sensor will enter the test mode You may test if installed position is good or not by this way After finish the test and decide to fix then you c...

Page 7: ...est mode Notice Bit0 and bit1 will effect when the DIP Switch setting to program mode If bit1 is enabled the bit0 is useless Bit2 Reserved always 1 Bit3 Setting the temperature scale 0 Fahrenheit 1 Celsius Bit4 Disable illumination report after event triggered Bit5 Disable temperature report after event triggered 6 Multi Sensor Function Switch 4 0 127 Multi Sensor function switch Using bit to cont...

Page 8: ...ture Time 12 1 127 The interval time for auto report the temperature 30 minutes per tick and minimum time is 30 minutes default tick is 12 6 hours Z Wave Supported Command Class COMMAND_CLASS_CONFIGURATION COMMAND_CLASS_VERSION COMMAND_CLASS_SENSOR_BINARY_V2 COMMAND_CLASS_ASSOCIATION_V2 COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 COMMAND_CLASS_WAKE_UP_V2 COMMAND_CLASS_SENSOR_MULTILEVEL_V5 COMMAND_CLASS...

Reviews: