background image

“Sensor Multilevel Report” to the nodes in the group 1.

Sensor Type: Luminance (0x03)

Note: To disable this functionality by setting the configuration setting

N0.5, the bit4 of the value to 1.

* Timing Report:

Beside   the   event   triggered   could   report   message,   the   device   also

support the timing unsolicited report of the status.

Battery level report: Every 6 hours report once in default.

It could be changed by configuration setting NO. 10.

Low battery report: When the battery level is too low, every 30

minutes will report once.

Illumination level report: Every 6 hours report once in default.

It could be changed by configuration setting NO. 12.

Temperature report: Every 6 hours report once in default.

It could be changed by configuration setting NO. 13.

Power Up Procedure

* Battery Power Check

When   the   power   up,   the   device   will   detect   the   power   level   of   the

battery immediately. If the power level is too low, the LED will continue

flash about 5 seconds. Please change another new battery.

* PIR Warm Up

When the power on, the PIR need to warm up before operation. The

warm up time about 1 minute, the LED will flash in every 2 seconds.

After finish the procedure the LED will light ON three times.

* NWI

When the power on, the device will check is it already adding to the

network? If doesn't, it will auto start the NWI mode. The LED will flash

in every second and continue 30 seconds. Until timeout or the device

successful to inclusion by controller.

* Wake

When the power on, the device will wake about 20 seconds. In this

duration, the controller can communicate with the device. Normally the

device is always sleeping to save the battery energy.

Function DIP Switch

There is one function DIP switch in front of the device.

Remove the front cover in the right top of the PCB, and also has mark

“M1” and “M2” for two switch.

M1 M2

Description

ON ON Test Mode.
ON OFF Security Mode.

OFF ON Home Automation Mode.

OFF OFF Program Mode. According to the configuration setting 

NO. 5 to set the operation mode.

Operation Mode

There are three operation modes of the device. The user can choosing

the suitable mode for application.

There are three modes “Test”, “Home Automation” and “Security”. 

“Test Mode” is for the user test the sensor function when installation.

“Home  Automation Mode”  focus in automatic  to control the  lighting

equipment. For convenience and save energy.

“Security Mode” focus in surveillance, warning.

When the event triggered, normally the LED won't indicated, unless the

battery is in the low level, the LED will flash once. And in the “Test

Mode” the LED also will light ON one second.

w w w . e k t

2

. c o m

Electronics 

Katrangi

 Trading

Summary of Contents for TSP01

Page 1: ...f them can inclusion exclusion reset or association from Z WaveTM network In the first time add the device into the Z WaveTM network First make sure the primary controller is in the inclusion mode And then power on the device just take out the insulation Mylar in the back side of the device The device will auto start the NWI Network Wide Inclusion mode And it should be included in 5 seconds You wi...

Page 2: ...ront cover and press the tamper key once The device will wake up 10 seconds Z WaveTM Message Report Motion Report When the PIR motion detected the device will unsolicited to send the Sensor Binary Report to the nodes in the group 1 Sensor Type Motion 0x0C Sensor Value 0xFF Tamper Report When the 2 tamper keys in the device are pressed over 5 seconds The device will into the alarm state In that sta...

Page 3: ... on the device will check is it already adding to the network If doesn t it will auto start the NWI mode The LED will flash in every second and continue 30 seconds Until timeout or the device successful to inclusion by controller Wake When the power on the device will wake about 20 seconds In this duration the controller can communicate with the device Normally the device is always sleeping to sav...

Page 4: ...ion setting NO 4 the device will emit the signal to turn ON the lighting equipment those nodes in the group 2 And delay a while to turn OFF the lighting equipment The delay time is setting by the configuration setting NO 9 The PIR motion re detected interval in the Test Mode fixed to 6 seconds In the Home Automation Mode will start detect before turn OFF the lighting equipment In the Security Mode...

Page 5: ... the front cover and pull back 3 Hold the front cover and pull up Replace the new battery and install the cover back 1 Put the front cover bottom to 1 1 and press down 2 Push the front cover top to 2 1 Choosing a Suitable Location 1 The recommended mounting height is 160cm 2 Don t let the device facing the window or the sunlight 3 Don t let the device facing the source of heat Like heater w w w e ...

Page 6: ...o as A tape and another is thinner hereinafter referred to as B tape you can use A tape for the test at the beginning The right way for A tape installation is stick it to the position below tamper key The thicker tape won t let the tamper key close so the sensor will enter the test mode You may test if installed position is good or not by this way After finish the test and decide to fix then you c...

Page 7: ...est mode Notice Bit0 and bit1 will effect when the DIP Switch setting to program mode If bit1 is enabled the bit0 is useless Bit2 Reserved always 1 Bit3 Setting the temperature scale 0 Fahrenheit 1 Celsius Bit4 Disable illumination report after event triggered Bit5 Disable temperature report after event triggered 6 Multi Sensor Function Switch 4 0 127 Multi Sensor function switch Using bit to cont...

Page 8: ...ture Time 12 1 127 The interval time for auto report the temperature 30 minutes per tick and minimum time is 30 minutes default tick is 12 6 hours Z Wave Supported Command Class COMMAND_CLASS_CONFIGURATION COMMAND_CLASS_VERSION COMMAND_CLASS_SENSOR_BINARY_V2 COMMAND_CLASS_ASSOCIATION_V2 COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 COMMAND_CLASS_WAKE_UP_V2 COMMAND_CLASS_SENSOR_MULTILEVEL_V5 COMMAND_CLASS...

Reviews: