Adding sound-insulating material into the cabinet (DK50 2V/50)
A component from the sound-insulating material is to be installed in the opening of the cabinet of
the compressor without a dryer.
This component is provided in the basic equipment delivered with the product.
A
B
C
Valve installation on the condensate drain from the cabinet (DK50 2x2V/110)
(Fig. 6)
For cabinet-mounted compressors, install the threaded fitting with the valve (1) into the hole in the
side of the cabinet and install the PA Ø 8 / Ø 6 hose (2). Insert the other side of the hose into the
fitting (4) beneath the air tank from which the valve (3) and hose are removed.
Use a Ø16.5 plug to close off the hole on the other side of the cabinet.
The fitting with the valve are standard parts delivered with the cabinet. The condensate drain valve
may be installed on either side of the compressor.