DK50 2V/50
DK50 2x2V/110
NP-DK50 2V 50, 2x2V 110-13_06-2020-MD A
-48-
06/2020
Prolonged operation
of the compressor
Leak from pneumatic distribution
system
Worn piston ring
Inlet filter is plugged
Defective solenoid valve
Check compressed air distribution
system – seal loose joint
Replace worn piston ring
Replace old filter with a new filter
Repair or change the valve or coil
Compressor is
noisy (knocking,
metal noises)
Damaged piston bearing, piston rod,
motor bearing
Loose or cracked spring
Replace damaged bearing
Replace damaged spring
Dryer doesn't dry
(condensed water in
the air) *
Cooling fan not working
Replace the fan
Check the power source
Damaged dryer
Replace the dryer
Non-functioning automatic
condensate drain
Clean / replace
)* After a dryer malfunction, the interior surfaces of the air tank must be thoroughly cleaned and all
condensed liquid removed.
Check the dew point of the air leaving the air tank (see Chapter 7 - Technical data) to protect
the device from damage!
REPAIR SERVICE
Guaranteed and post-guarantee repairs must be done by the manufacturer, its authorized
representative, or service personnel approved by the supplier.
The manufacturer reserves the right to make changes to the device without notice. Any
changes made will not affect the functional properties of the device.
STORAGE
If the compressor will not be used for a prolonged time period, drain all condensate from the air
tank. Then turn on the compressor for 10 minutes, keeping the drain valve open (1) (Fig. 14).
Switch off the compressor using the switch (2) at the pressure switch (1) (Fig. 13), close the drain
valve and disconnect the device from the mains.
DISPOSAL OF THE DEVICE
Disconnect the device from the mains.
Release air pressure in the pressure tank by opening the drain valve (1) (Fig. 14).
Dispose of the device following all applicable environmental regulations.
Entrust a specialised company to sort and dispose of waste.
Worn out components have no negative environmental impact.
Summary of Contents for DK-50 2x2V/110
Page 2: ......
Page 4: ...CONTENTS 1 INHALT 49 SOMMAIRE 97 ОГЛАВЛЕНИЕ 145 ...
Page 25: ...DK50 2V 50 DK50 2x2V 110 06 2020 21 NP DK50 2V 50 2x2V 110 13_06 2020 MD A 3B DK50 2x2V 110S ...
Page 73: ...DK50 2V 50 DK50 2x2V 110 06 2020 69 NP DK50 2V 50 2x2V 110 13_06 2020 MD A 3B DK50 2x2V 110S ...
Page 121: ...DK50 2V 50 DK50 2x2V 110 06 2020 117 NP DK50 2V 50 2x2V 110 13_06 2020 MD A 3B DK50 2x2V 110S ...
Page 169: ...DK50 2V 50 DK50 2x2V 110 06 2020 165 NP DK50 2V 50 2x2V 110 13_06 2020 MD A 3B DK50 2x2V 110S ...
Page 202: ...No text ...
Page 203: ...No text ...