background image

 

0521 IH-9485VND

Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. 
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or 
property damage! Retain instructions for future reference.

REMINDER: Keep your dated proof of purchase for warranty purposes! 

Attach it to this manual or file it for safekeeping.

IN641400AV 12/15

See Warranty on page 12 for important information about commercial use of this product.

Operating Instructions and Parts Manual 

DC1300

© 2015 Campbell Hausfeld
A Marmon/Berkshire Hathaway Company

For parts, product & service information,

visit 

www.campbellhausfeld.com

Oil-Lubricated 

Compressors

Description

This oil-lubricated compressor is 
designed for do-it-yourselfers with a 
variety of home and automotive jobs. 
These compressors power spray guns, 
impact wrenches and other tools.  
Compressed air from this unit will 
contain moisture. Install a water filter 
or air dryer if application requires dry 
air.

Unpacking

After unpacking the unit, inspect 
carefully for any damage that may 
have occurred during transit. Make sure 
to tighten fittings, bolts, etc., before 
putting unit into service. In case of 
questions, damaged or missing parts, 
please call 1-800-543-6400 for customer 
assistance. Have the serial number, 
model number, and parts list (with 
missing parts circled) before calling.

DO NOT RETURN 
THE PRODUCT TO 
THE RETAILER!

 

Do not operate unit 

  

if damaged during 

shipping, handling or use. Damage may 
result in bursting and cause injury or 
property damage.

READ & FOLLOW ALL INSTRUCTIONS

SAVE THESE INSTRUCTIONS

DO NOT DISCARD 

 

Caution indicates 

  a potentially 

hazardous situation which, if not 
avoided, MAY result in minor or 
moderate injury.
 

Notice indicates 

 important 

information, that if not followed, 
may cause damage to equipment.

NOTE:

 Information that requires special 

attention.

Safety Guidelines

This manual contains information 
that is very important to know and 
understand. This information is 
provided for SAFETY and to PREVENT 
EQUIPMENT PROBLEMS. To help 
recognize this information, observe the 
following symbols.

 

Danger indicates 

  an imminently 

hazardous situation which, if not 
avoided, WILL result in death or 
serious injury.
 

Warning indicates 

  a potentially 

hazardous situation which, if not 
avoided, COULD result in death 
or serious injury.

Breathable Air Warning 

This compressor / pump is not 
equipped and should not be 
used “as is” to supply breathing 
quality air. For any application of 
air for human consumption, the 
air compressor / pump will need 
to be fitted with suitable in-line 
safety and alarm equipment. 
This additional equipment is 
necessary to properly filter 
and purify the air to meet 
minimal specifications for 
Grade D breathing as described 
in Compressed Gas Association 
Commodity Specification 
G 7.1 - 1966, OSHA 29 CFR 1910. 
134, and / or Canadian Standards 
Associations (CSA).

DISCLAIMER OF WARRANTIES
In the event the compressor is 
used for the purpose of breathing 
air application and proper in-line 
safety and alarm equipment is 
not simultaneously used, existing 
warranties shall be voided, and 
the manufacturer disclaims any 
liability whatsoever for any loss, 
personal injury or damage.

STOP!

Record the Model No., Serial No. and 
date of purchase located on the base 
below the pump in the space below.
Model No.  ________________________
Serial No.  _________________________
Date of purchase  _________________

Retain these numbers for 

future reference.

H-9485

Summary of Contents for DC1300

Page 1: ...ESE INSTRUCTIONS DO NOT DISCARD Caution indicates a potentially hazardous situation which if not avoided MAY result in minor or moderate injury Notice indicates important information that if not follo...

Page 2: ...nt and controls can cause electrical arcs that will ignite a flammable gas or vapor Never operate or repair in or near a flammable gas or vapor Never store flammable liquids or gases in the vicinity o...

Page 3: ...e of contamination This debris will damage the motor ELECTRICAL INSTALLATION All wiring and electrical connections should be performed by a qualified electrician Installation must be in accordance wit...

Page 4: ...ssor will build to maximum pressure and shut off 5 With hose attached to outlet of compressor attach tire chuck or other tool to open end of hose 6 Adjust regulator to proper pressure for tool or tire...

Page 5: ...element and inspect 3 If the filter element is dirty or clogged replace it 4 Reinstall filter and cover IMPORTANT Locate unit as far from spraying area as hose will allow to prevent overspray from clo...

Page 6: ...bing etc 1 Check all connections with soap and water solution Tighten or remove and apply pipe dope or pipe tape to the threads then reassemble 2 Open tank drain valve 2 Close tank drain valve 3 Tank...

Page 7: ...ader valve 7 Defective motor capacitor s 7 Replace capacitor s 8 Defective motor 8 Replace motor 9 Lack of proper ventilation room temperature too high 9 Move compressor to well ventilated area 10 Clo...

Page 8: ...8 Operating Instructions and Parts Manual www campbellhausfeld com 17 15 14 13 10 11 8 7 5 6 33 34 35 37 18 19 16 20 12 28 29 30 31 32 21 23 22 24 25 27 26 22 36 4 3 2 1 38 9 Figure 7 Repair parts ill...

Page 9: ...1 9 PRESSURE SWITCH 1 10 TANK GAUGE 1 11 SAFETY VALVE 1 12 CONNECT 1 13 OUTLET GAUGE 1 14 REGULATOR 1 15 COUPLER 1 16 TANK 1 17 POWER CORD 1 18 HANDLE 1 19 HANDLE GRIP 1 20 CONNECT 1 21 M8X30 BOLT 4 2...

Page 10: ...nstructions and Parts Manual www campbellhausfeld com Figure 8 Repair parts illustration for pump motor 27 25 24 23 22 21 20 19 41 40 39 38 37 34 33 30 35 1 2 4 5 6 7 8 10 11 12 12 13 14 9 31 32 28 16...

Page 11: ...2 M4 NUT 4 33 M8 NUT 1 34 CAPACITOR 1 35 BEARING 1 36 REAR BEARING CRANK 1 37 M5 WASHER 4 38 M5 SPRING WASHER 4 39 M5X110 MOTOR BOLT 4 40 COOLING FAN 1 41 EXTERNAL RETAINING RING FOR 14MM SHAFT 1 REPL...

Page 12: ...sed by rain excessive humidity corrosive environments or other contaminants c Cosmetic defects that do not interfere with compressor functionality d Rusted tanks including but not limited to rust due...

Page 13: ...ves de S curit Ce manuel contient de l information tr s importante qui est fournie pour la S CURIT et pour VITER LES PROBL MES D QUIPEMENT Rechercher les symboles suivants pour cette information Dange...

Page 14: ...es commandes lectriques peuvent causer des arcs lectriques qui peuvent allumer un gaz ou une vapeur inflammable Ne jamais utiliser ou r parer le mod le pr s d un gaz ou d une vapeur inflammable Ne jam...

Page 15: ...ar des objets Ne pas situer la prise d air du compresseur pr s de la vapeur un jet pulv ris de peinture endroits de d capage au sable ou autre sources de contamination Le d bris endommagera le moteur...

Page 16: ...ns le sens antihoraire pour fermer le d bit d air 3 Tourner l interrupteur la position AUTO AUTOMATIQUE 4 Le compresseur accumulera la pression jusqu ce qu il atteint la pression maximum et s arr tera...

Page 17: ...rage 5 Changer l huile apr s chaque 50 heures d usage ENTRETIEN DU FILTRE D AIR D ASPIRATION Retrait inspection et remplacement Figure 6 Il faut retirer l l ment du filtre d aspiration et le v rifier...

Page 18: ...ape de retenue us e 3 Remplacer la soupape de retenue Ne pas d monter le clapet de non retour avec de l air dans le r servoir purger le r servoir 4 Soupape de d charge d fectueuse sur le manostat 4 Re...

Page 19: ...ifier tous les connexions lectriques 5 Soupape de retenue us e 5 Remplacer la soupape de retenue Ne pas d monter le clapet de non retour avec de l air dans le r servoir purger le r servoir 6 Soupape d...

Page 20: ...tructions d Utilisation et Manual de Pi ces Figure 7 Illustration des pi ces de r paration pour mod le HL540200 17 15 14 13 10 11 8 7 5 6 33 34 35 37 18 19 16 20 12 28 29 30 31 32 21 23 22 24 25 27 26...

Page 21: ...9 MANOSTAT 1 10 MANOM TRE DU R SERVOIR 1 11 SOUPAPE DE S CURIT 1 12 CONNECTEUR 1 13 MANOM TRE DE SORTIE 1 14 R GULATEUR 1 15 COUPLEUR 1 16 R SERVOIR 1 17 CORDON D ALIMENTATION 1 18 POIGN E 1 19 POIGN...

Page 22: ...Utilisation et Manual de Pi ces Figure 8 Illustration des pi ces de r paration pour le pompe moteur HL360000AV 27 25 24 23 22 21 20 19 41 40 39 38 37 34 33 30 35 1 2 4 5 6 7 8 10 11 12 12 13 14 9 31 3...

Page 23: ...ON 1 15 BAGUE DE RETENUE EXTERNE POUR ARBRE DE 12 MM 2 16 BIELLE 1 17 VIS M8 X 22 LH 1 18 EXCENTRIQUE 1 19 STATOR 1 20 ROTOR 1 21 ROULEMENT 1 22 JOINT D TANCH IT DU ROULEMENT 1 23 CARTER 1 24 JOINT D...

Page 24: ...ur le fonctionnement du compresseur d Les r servoirs rouill s y compris mais sans s y limiter la rouille caus e par la vidange incorrecte ou par un environnement corrosif e Les composants suivants son...

Page 25: ...ESTAS INSTRUCCIONES NO LAS DESECHE Medidas de Seguridad Este manual contiene informaci n que es muy importante que sepa y comprenda Esta informaci n se la suministramos como medida de SEGURIDAD y para...

Page 26: ...re el compresor cerca de gases o vapores inflamables Nunca almacene l quidos o gases inflamables cerca del compresor Las piezas del compresor podr an estar calientes inclusive cuando la unidad est apa...

Page 27: ...l motor INSTALACI N EL CTRICA Todas las conexiones el ctricas y el alambrano deber n ser llevados a cabo por un electricista profesional La instalaci n debe estar conforme con los c digos locales y lo...

Page 28: ...NAMIENTO 1 Coloque el interruptor en OFF y conecte el cord n al tomacorrientes 2 Gire la perilla del regulador en sentido antihorario para cerrar el flujo de aire 3 Coloque el interruptor en AUTO 4 El...

Page 29: ...o u obstruido c mbielo 4 Vuelva a instalar el filtro y la cubierta IMPORTANTE Para prevenir que el exceso de pulverizaci n atore el filtro coloque la unidad tan lejos del rea de pulverizaci n como le...

Page 30: ...uber as etc 1 Revise todas las conexiones con una soluci n de agua y jab n Apriete o retire y aplique sellador o cintas para roscas luego vuelva a ensamblar 2 Abra la v lvula de drenaje del tanque 2 C...

Page 31: ...oso s 7 Reemplace el condensador es 8 Motor defectuoso 8 Cambie el motor 9 Falta de ventilaci n adecuada temperatura ambiente demasiado alta 9 Mueva el compresor a un rea bien ventilada 10 El filtro d...

Page 32: ...trucciones y Lista de Piezas 32 Sp Figura 7 Ilustraci n de las piezas de repuesto para modelo HL540200 17 15 14 13 10 11 8 7 5 6 33 34 35 37 18 19 16 20 12 28 29 30 31 32 21 23 22 24 25 27 26 22 36 4...

Page 33: ...DE PRESI N 1 10 MEDIDOR DE TANQUE 1 11 V LVULA DE SEGURIDAD 1 12 CONECTOR 1 13 MEDIDOR DE SALIDA 1 14 REGULADOR 1 15 ACOPLADOR 1 16 TANQUE 1 17 CABLE DE ALIMENTACI N 1 18 MANIJA 1 19 AGARRADERA DE MA...