Procedure for connecting a compressor disconnected from the cabinet
Prior to any maintenance or repair work, switch off the compressor and
disconnect it from the mains (pull out the mains plug).
The compressor (without cabinet) requires that the jumper is always mounted in the terminal strip
for correct operation (Fig. 19, Fig. 20 Pos. D). It then replaces the switch on the cabinet.
If there is no jumper in the terminal strip of the compressor (disconnected from
the cabinet), the compressor will not work!
If the cord between the compressor and the cabinet becomes disconnected (by pulling the mains
plug) and the compressor is removed from the cabinet, the compressor will not be functional.
Therefore, it is necessary to first create a connection to the terminal strip with a jumper (replacing
the circuit breaker function) (Fig. 19, Fig. 20 Pos. A).
PROCESS:
Jumper installation (A-B-C-D proces)
Disconnect the product from the mains by pulling the plug out of the socket.
Remove the cover on the electrical panel (on the compressor).
The jumper is not in the terminal strip – A.
Lift up the fuse cover – B.
Insert the jumper into the terminal strip – C.
Close the fuse cover – D.
Reinstall the cover on the electrical panel.
Connect the device to the electrical mains.
Activate the compressor by turning on the switch on the pressure switch.
Compressor - when operating outside the cabinet, the electrical connection with an installed
jumper
MUST
be created (Fig. 19, Fig. 20 Pos. D).
Summary of Contents for DK-50 2x2V/110
Page 2: ......
Page 4: ...CONTENTS 1 INHALT 49 SOMMAIRE 97 ОГЛАВЛЕНИЕ 145 ...
Page 25: ...DK50 2V 50 DK50 2x2V 110 06 2020 21 NP DK50 2V 50 2x2V 110 13_06 2020 MD A 3B DK50 2x2V 110S ...
Page 73: ...DK50 2V 50 DK50 2x2V 110 06 2020 69 NP DK50 2V 50 2x2V 110 13_06 2020 MD A 3B DK50 2x2V 110S ...
Page 121: ...DK50 2V 50 DK50 2x2V 110 06 2020 117 NP DK50 2V 50 2x2V 110 13_06 2020 MD A 3B DK50 2x2V 110S ...
Page 169: ...DK50 2V 50 DK50 2x2V 110 06 2020 165 NP DK50 2V 50 2x2V 110 13_06 2020 MD A 3B DK50 2x2V 110S ...
Page 202: ...No text ...
Page 203: ...No text ...