9
CURRENTSENSE
FAULT
4.1
Current detection fault
2) Electromagnetic brake drive open
circuit
EEPROM CHECKSUM
FAULT
4.3
EEPROM failure
1) Electromagnetic brake coil open
HARDWARE FAILSAFE
4.2
Motor voltage is out of
range
2) Electromagnetic brake drive short
circuit
HPD FAULT
3.5
HPD fault
1) Short circuit of motor or motor wiring
MAIN FAULT
2.3
The main contactor is
faulty
2) The controller is faulty
MAIN OFF FAULT
2.1
Main contactor coil drive
'off' failure
1) EEPROM is faulty or invalid
MAIN ON FAULT
2.4
Main contactor coil drive
'on' failure
1) Motor voltage cannot match
accelerator input
OVERVOLTAGE FAULT
1.5
Battery voltage is too
high
2) Short circuit of motor or motor
matching ring
PRECHARGE FAULT
3.3
Precharge failure
3) The controller is faulty
SPEED POT FAULT
1.3
The speed limiting
potentiometer is faulty
1) Accelerator, key switch, promotion or
prohibition
THERMAL FAULT
1.1
Over/under temperature
cut-off
Input several actions out of order
Summary of Contents for EK07S Series
Page 1: ...SERVICE MANUAL EK07S Series Counter Balanced Stacker...
Page 16: ...14 Using an inner hexagon wrench adjust the pressure...
Page 17: ...15 a Schematic diagram and wiring diagram EK05S Electrical Schematic diagram...
Page 18: ...EK07S Electrical Schematic diagram...
Page 19: ...B Hydraulic circuit Hydraulic circuit...
Page 22: ...20 B Removal of electric control component...
Page 23: ...21 B Removal of electric control component No Code name Specificatio n qua nti ty rem ark...
Page 25: ...23 c Hydraulic assembly removal 1 GB T 41 2000 Hexagonal nut M6 5...
Page 27: ...25...
Page 28: ...26 No Code Name Specification Quant ity Remark...
Page 31: ...29 NO Code Name Specificat ion Quanti ty Remark...