Electronic convection oven rev. 5 _________________________________________MODELS EKF 464 TC – EKF 511 TC
_________________________________________________________________________________________ page 7
-
the limiting valve and the system are able to withstand the appliance's load (see "technical
data" plate);
-
the power supply system is fitted with effective earthing connection according to the
regulations in force;
-
In the permanent connection to the mains, a
protective pole switch must be provided
between the appliance and the mains with minimum opening between the contacts of
overvoltage category III (4000V), sized for the load and complying with applicable
regulations (e.g. automatic magnetic circuit breaker);
-
the pole switch used for the connection is easily accessible with installed appliance;
-
the yellow/green earthing cable is not interrupted by the switch;
-
The appliance must be connected to an equipotential system the effectiveness of which
must be suitably assessed according to applicable regulations. This connection must be
performed with the suitable terminal located on the rear and marked with the symbol .
The equipotential conductor must have minimum section 2.5mm
²
.
-
when the appliance is operating, the power supply voltage does not deviate from the
nominal voltage value by ±10%;
-
ensure the power supply cable does not enter in contact with the appliance's hot parts
after inserting it in the terminal board.
-
if the power supply cable is damaged it must be replaced by the manufacturer or their
technical support service, or in any case by a person with similar qualifications, to prevent
any risk.
Installation and connection drawings
Fig. 1 (Dimensions are expressed in mm )
1 USB PORT
3 SOCKET FOR CORE PROBE CONNECTION
4 WATER DRAIN PIPE (DN30)
5 WASHING WATER INLET
6 SOFTENED WATER INLET (THREADED SOLENOID VALVE
¾
”)
8 STEAM VENT
9 POWER SUPPLY CABLE RETAINER
10 WARNING HOT SURFACE
11 DO NOT OBSTRUCT AERATION VENTS
12 WATER INLET MAX.200kPa
13 SOFTENED WATER INLET MAX. 200kPa