GB
- 17 -
4. Technical data
Rated voltage: ........................................ 18V DC
Protection class: ................................................III
Max. working pressure: ...........1.10 MPa (11 bar)
Automatic mode pressure min.: 20 kPa (0.20 bar)
Automatic mode pressure max.: ..........................
.................................................1.10 MPa (11 bar)
ON time max.: ...........................................10 min
Output for compressed air at 0 bar ..........12 l/min
Output for compressed air at 4 bar ............8 l/min
Output for compressed air at 7 bar ............6 l/min
Compressor idling speed .................16,500 min
-1
Length of compressed air hose approx.: ....60 cm
Approx. weight without battery: ..................0,8 kg
Danger!
Sound and vibration
The noise emission values were measured in ac-
cordance with EN 62841.
L
pA
sound pressure level ..................... 69.6 dB(A)
K
pA
uncertainty .............................................3 dB
L
WA
sound power level ....................... 80.6 dB(A)
K
WA
uncertainty .............................................3 dB
Wear ear-mu
ff
s.
The impact of noise can cause damage to hea-
ring.
Caution!
The equipment is supplied without batteries and
without a charger and is allowed to be used only
with the lithium-ion batteries of the Power-X-
Change series!
The lithium-ion batteries of the Power-X-Change
series are allowed to be charged only with
Power-X chargers.
Total vibration values (vector sum of three direc-
tions) determined in accordance with EN 62841.
Handle
Vibration emission value a
h
= 7.59 m/s
2
K uncertainty = 1.5 m/s
2
The stated vibration emission levels and stated
noise emission values were measured in ac-
cordance with a set of standardized criteria and
can be used to compare one power tool with
another.
The stated vibration emission levels and stated
noise emission values can also be used to make
an initial assessment of exposure.
Warning:
The vibration and noise emission levels may vary
from the level speci
fi
ed during actual use, depen-
ding on the way in which the power tool is used,
especially the type of workpiece it is used for.
Keep the noise emissions and vibrations to a
minimum.
•
Only use appliances which are in perfect wor-
king order.
•
Service and clean the appliance regularly.
•
Adapt your working style to suit the appliance.
•
Do not overload the appliance.
•
Have the appliance serviced whenever ne-
cessary.
•
Switch the appliance off when it is not in use.
Caution!
Residual risks
Even if you use this electric power tool in
accordance with instructions, certain resi-
dual risks cannot be rules out. The following
hazards may arise in connection with the
equipment’s construction and layout:
1. Damage to hearing if no suitable ear protec-
tion is used.
2. Health damage caused by hand-arm vib-
rations if the equipment is used over a pro-
longed period or is not properly guided and
maintained.
Danger!
The electric power tool generates an electro-
magnetic
fi
eld during operation. Under certain
circumstances this
fi
eld may actively or passively
impede medical implants. To reduce the risk of
serious or fatal injuries, we recommend persons
with medical implants to consult their doctor and
the manufacturer of the medical implant prior to
using the equipment.
Anl_CE_CC_18_Li-Solo_SPK13.indb 17
Anl_CE_CC_18_Li-Solo_SPK13.indb 17
19.05.2021 12:28:19
19.05.2021 12:28:19