GB
- 19 -
To remove the battery, proceed as described in
section 5.1.
6. Operation
6.1 Switching the equipment on and / o
ff
a) Switching on
Press the button Fig. 7 / Item 9b to switch on the
equipment; the display will appear.
b) Switching o
ff
•
Press button Fig. 7 / Item 9b for approx. 2 se-
conds; the display will disappear.
•
The equipment switches off automatically
after approx. 5 minutes of non-activity; the
display will also disappear.
6.2 Display (Fig. 7)
•
In the upper region of the display (9a) the
pressure set for automatic mode will appear
starting with 0.30 bar / 30 kPa / 5.0 PSI.
•
In the lower region of the display you will see
the pressure reached at the pressure hose.
If there is already pressure in the object you
want to inflate when you attach the pressure
hose, this pressure will be indicated after the
equipment is switched on.
6.3 Adjustments in automatic mode (Fig. 7)
•
The unit of the displayed pressure can be se-
lected with the button (9b). The pressure can
be displayed in units of [bar], [PSI] or [kPa].
•
Use the button (9c) to reduce the desired
pressure.
•
Use the button (9d) to increase the desired
pressure.
6.4 Automatic mode / manual mode (Fig. 6)
a) Automatic mode
•
You can switch the equipment to automatic
mode by pressing the “AUTO” switch position
(Item 7a) of the On/Off/Automatic switch. The
compressor will then pump until the pres-
sure that was preselected on the display is
reached; then it will switch off.
b) Manual mode
•
You can switch the equipment to manual
mode by pressing the “MANUAL” switch posi-
tion (Item 7b) of the On/Off/Automatic switch.
The compressor will then pump until you re-
lease the switch.
6.5 Compressor compressed air mode
•
Connect the adapter (Fig. 1 / Item 5a) of the
compressed air hose to the object you want
to inflate. Flip over the fastening lever (Fig. 1 /
Item 5b) to secure the adapter on the valve or
the valve adapter.
•
Depending on what you are inflating, also use
the adapters (10, 11, 12) or other adapters
available from retail stores.
•
Switch on the equipment and consult section
6.1 – 6.4 to make the settings to suit your
needs.
•
Warning!
Note that in manual mode the com-
pressor does not switch off automatically but
will continue inflating the connected object
until the maximum pressure is reached or the
object bursts.
•
Warning!
Observe the information supplied
by the tire manufacturer and the vehicle ma-
nufacturer relating to the recommended tire
pressure.
•
Warning!
This equipment is not calibrated!
For a calibrated measurement value, check
the actual tire pressure using a calibrated me-
ter after you have inflated the tires yourself,
e.g. at a petrol station.
•
Allow the compressor to cool down for about
10 minutes after every 10 minutes of operati-
on in order to prevent overheating.
7. Cleaning, maintenance and
ordering of spare parts
Danger!
Always take the battery out of the equipment
and pull out the power plug before starting any
cleaning work.
7.1 Cleaning
•
Keep all safety devices, air vents and the
motor housing free of dirt and dust as far as
possible. Wipe the equipment with a clean
cloth or blow it with compressed air at low
pressure.
•
We recommend that you clean the device
immediately each time you have finished
using it.
•
Clean the equipment regularly with a moist
cloth and some soft soap. Do not use
cleaning agents or solvents; these could at-
tack the plastic parts of the equipment. Ensu-
re that no water can seep into the device. The
ingress of water into an electric tool increases
Anl_CE_CC_18_Li-Solo_SPK13.indb 19
Anl_CE_CC_18_Li-Solo_SPK13.indb 19
19.05.2021 12:28:19
19.05.2021 12:28:19