11. Error Table
Error codes that may appear on the Ron 2000 indicatordisplay
Error
No.
Description
E=Eilon only
S=User
Serviceable
E1, E2, E3 EEprom Erron Read/Write
E
001
Calibration or EEprom memory error
E
002
Calibration Baud Watch Timer
E
003
Scrolling Capacity 10% higher than allowed. Recalibrate. Do not load
the system with a weight higher than the test load.
S
005
ZeroTracing
E
007
Totalizer sum value overflow.
Reset the Totalizer according to manual. Only applicable if Totalizer
was ordered
E
008
Data Logger memory overflow.
Reset according to manual (see Data Logger). Only applicable if Data
Logger was ordered
S
009
Data Logger or Eeprom error.
Reset "Data Logger" according to the manual
S
010
Data Logger already active. Wait 5 seconds and Reset Data Logger.
S
011
Eeprom failure
E
015
Active Real time Clock (RTC) power. Check/Replace battery.
020
RS232 or SetPoint still active - wait several seconds and try again.
S
25-26
Eeprom ON/OFF Write/Read.
E
31-34
Reset according to manual (see Totalizer).
S
40
Tare attempted above capacity.
45
Zero Setting: Zero value above 30% of capacity. Reset zero value.
S
46
(Multi) Zero = Sum, Tare = Sum
S
49-59
Keyboard error. A key has been pressed more than 3 seconds or
problem with connectors. Check connectors.
S
60-61
Check manual (see Tare). Never use Tare if there is no Tare.
S
070
Multiplication factor failure (see manual Multi-Load).
S
090
Temperature3 > MAX above 80 deg. Celsius
E
100
Wrong DecPoint
E
102
Data logger does not exist. Read manual.
S
103
Menu: Time. Real Time Clock received incorrect data. See manual.
S
104
Check baudrate according to manual.
S
111
Failure in initial callibration
E
118
Watch Dog Trigger
E
132
Init WatchTimer
E
150
Units: Capacity > 99999
S