_NV Ron 2000 4.2
9/37
3/25/2016
To use the tare mode, load the system with the desired container and then press
TARE
. The screen will display
NET
, then the value of 0. The system is now in
Net mode. To exit out of Net mode, press
TARE
again.
GROSS
will appear
indicating that the system is back in Gross mode. The system will show
NET
on
the screen about once every minute as a reminder that it is in Net mode. Note
that switching between Gross and Net modes will clear the MAX (see MAX
section).
CAUTION
:
When measuring loads using a shifted zero with the tare function, the actual load
is the value indicated on the readout
plus
that of the shifted zero or tare.
4. Max (a.k.a. Peak Hold)
Checking the maximum registered load value
T
he system features a MAX (aka PEAK HOLD) function. MAX will store
the maximum weight that the system has detected since it was last powered
on or since the Gross/Net mode was changed.
Press the
MAX
key until the display shows
:M:AX
. It will then display the
current maximum load the system has registered since the last time the MAX
was reset. The weight will be displayed for approximately two seconds with
colons in between the digits. These simply serve as a visual indicator that the
displayed value is the stored max and not the current weight. The system
will go back to the current value then a beep will sound indicating that the
system is ready for a new operation.
The MAX memory is cleared every time the system is powered down or the
mode is changed between Net and Gross. If the system is equipped with the
user selectable units options, the MAX will also be reset if the unit of
measurement is changed (see UNITS section).