5. Overload Warnings
Two level visual overloadwarning
T
he system features a two level visual overload warning. When loaded to
100% of its maximum capacity an up, the displayed weight will flash on and
off continuously. Should this occur, the lift should be terminated
immediately and the current load set down.
Should the system be drastically overloaded (130% of max capacity),
DANG.R
(short for danger) will appear on the display. Only when the
system is completely unloaded and the measured value reduced to zero will
the
DANG.R
message disappear.
Should this occur, it is essential that the Ron system and all accompanying
rigging accessories are checked by an authorized inspector before being used
again.
Please note that both overload warnings remain functional at the same levels
(100% & 130% of full capacity) whether the system is in Gross or Net mode.
This means that when tare is used, you may see an overload warning at a
displayed value that is less then 100% of capacity.
All overloads are dangerous to personnel and should be avoided at all costs.
Overloading the system can also result in costly damage to the system itself.
6. Power Saving Mode
Low energy consumption for longer batterylife
I
f the system detects a zero value for a 60 second period, it will enter power
saving mode and display
--0--
on the screen. This feature helps save battery
power. The system will check the value every 5 second and will awaken if a
value other than zero is detected.