_NV Ron 2000 4.2
21/37
3/25/2016
When the system is first turned on, it will output a lead section of six lines.
The first five of these are the system's owner identification info and must be
factory set. If no instructions were giving at the time of ordering, these lines
will be blank. Each line includes up to 60 characters.
A printed data record line includes the following:
1. The load (up to 5 digits)
2. The unit of measurement
3. TARE mode: NET or GROSS
4. Function: LOAD = reading taking directly from indicator.
MAX (PEAK HOLD) = max value reading
TOT. # = reading from totalizer memory. Value and
total number of loads
D.L. 1 = reading #1 from Data Logger memory
D.L. 2 = reading #2 from Data Logger memory
D.L. etc.
5. DATE & TIME – if the system is equipped with the
optional real time clock.
9.6 Baud Rate Selection (if included)
Enter into the options menu by following the instructions in section 9. Use
the arrow keys ↑↓ to scroll through the available options until you see
BAUD.R
and press
ENTER
. The display will show the current baud rate in
use. Use the arrow keys again to scroll through the available rates:
115,200 – 38,400 – 19,200 – 9,600
Press
ENTER
. The display will show
OK
, the selected baud rate, and then revert
back to the options menu. Press
ESC
to exit the options menu.
9.7 Analog Output
9.7.1 4÷20mA:
250
A
-Curr
--
+Curr
12
24V
9.7.2 0÷1V: (see Connector Cables section)