1.

 

Introduction 

The EHS Electric Boiler range will give years of trouble-free service and the following instructions will assist you in 

obtaining the best performance and most economical settings for your appliance. 

ATTENTION: Only qualified engineers and approved service engineers are recommended for installing and servicing 

this product. Unqualified personal and the use of nonstandard parts can be dangerous and will invalidate the 

manufacturer’s warranty. 

The installation must be performed in accordance with current IEE Wiring Regulations, Building Regulations, Water 

Fitting Regulations (England and Wales) or Water Bylaws (Scotland) and all relevant British standards. 

It is very important that you have read and fully understood this manual before installation of the EHS Electric 

Boilers to ensure their long life. This instruction manual should be kept in a place close to the appliance for easy 

reference. Please read the whole manual before attempting installation and follow these installation instructions 

and operating instruction to ensure long life of this EHS Boiler. These instructions must be conserved and given to 

any new user. 

All EHS Electric Boilers are guaranteed from manufacturing defects for a full 5 years. To ensure that you are eligible 

for this guarantee you must register the boiler at www.ehs-heating,com within the time specified in the warranty 

terms and conditions. This can be found at the back of this manual and on the EHS website. The warranty relates to 

any manufacturing defects and covers the replacement of any faulty parts. The guarantee does not cover any 

damage or faults that are a consequence of poor installation or faults caused by leaks within the boiler. It is 

therefore very important that all connections are thoroughly checked by the installer prior to leaving it with the 

customer. All work that takes place under the guarantee must be agreed with EHS prior to commencing the 

installation.  

This appliance must only be used and programmed by an authorised adult. It should not be used by children or 

anyone who has not read the installation manual. If in doubt, seek expert advice. 

 

 

2.

 

HEALTH AND SAFETY 

At EHS we take every precaution where possible to design and manufacture our products to meet the safety 

requirements, when installed and operated according to the correct procedures. All products are comprehensively 

examined and tested before despatch. 

Under the Consumer Protection Act 1974 it is a requirement to provide information on substances harmful or 

hazardous to health (COSHH Regulations 1988) 

Materials used in the manufacture of this appliance are non-hazardous and do not require any special precautions 

when fitting or servicing this appliance.  

It is the responsibility of the user or engineer to use the correct Personal Protective Equipment and Clothing when 

installing or working on this appliance.  

 

 

 

 

Summary of Contents for ALC1-1PCO12

Page 1: ...EHS Combination and System Boilers Installation Manual Heating for the Renewable Future Please read through the whole instructions before removing the boiler from its packaging and installing and ope...

Page 2: ...ICE UNDER NO CIRCUMSTANCES MUST THIS BOILER BE CONNECTED TO THE MAINS POWER WHILST THE BOILER IS DRY THE BOILER MUST BE FILLED WITH WATER AND PRESSURE TESTED PRIOR TO ELECTRICAL CONNECTION FAILURE TO...

Page 3: ...7 4 1 Flushing 7 4 2 Heating System Fill 7 4 3 Hot Water System Fill 7 5 Electrical Connections 7 5 1 Electricity Connection Precautions 7 5 2 Electrical Supply Connections 7 5 3 Thermostat connectio...

Page 4: ...he boiler at www ehs heating com within the time specified in the warranty terms and conditions This can be found at the back of this manual and on the EHS website The warranty relates to any manufact...

Page 5: ...reaker is used VOLTAGE AND LOAD TEST DONE CABLE SIZE mm BREAKER AMPS 3 6 Check the central heating design is suitable for the application Detailed recommendations are provided in BS EN 12828 and BS EN...

Page 6: ...trical installations IEE Wiring Regulations Seventeenth edition 4 1 7 BS EN 7593 Code of practice for treatment of water in heating systems 5 Unpacking and installation 5 1 These appliances can weigh...

Page 7: ...able Connector 1 4 Single valve 1 14 Water tank pipe 1 24 Body parts 1 5 Pressure switch 1 15 Pressure relief pipe 1 25 Expansion tank 5 litres left side 1 6 Pressure gauge 1 16 Pressure relief valve...

Page 8: ...ponents 1 5 DHW thermostat 60A 17 Water temperature probe D12 1 29 Wire 1 6 Pressure switch 1 18 Water temperature probe D18 1 30 Cable Connector 1 7 Pressure gauge 1 19 Water tank pipe 1 31 Body part...

Page 9: ...the electrical supply then you must install it in a fashion that prevents access to the boiler such as a lockable cupboard The wall that you choose to mount this boiler on should be strong enough to...

Page 10: ...10 www ehs heating com Screw 3 x screws into 3 upper expansion screw bolts Step Four Hang the boiler on the 3 fixed screws Then drill 2 screws into 2 under expansion screws...

Page 11: ...11 www ehs heating com 7 2 Design and connect the plumbing system 7 2 1 Typical S plan Layout for a system boiler...

Page 12: ...12 www ehs heating com 7 2 2 Typical Layout for Combination Boiler...

Page 13: ...d on the flow and return pipework from the boiler Standard ball valves will restrict flow and impede the flow in and out of the boiler which will result in poor performance AUTOMATIC AIRVENTS The EHS...

Page 14: ...red as overtightening of connections can twist and damage the internal pipework of the boiler which is not covered under the warranty An external magnetic filter must be used on all installations 7 3...

Page 15: ...automatic air vent behind the pump in the boiler to ensure its not screwed down It needs to be free moving 7 4 2 3 Connect the filling loop to the water replenishing connection 7 4 2 4 Open the replen...

Page 16: ...carried out when installing high power boilers 7 5 1 2 All electrical connections must be made by a fully qualified electrician 7 5 1 3 All wiring must be carried out in accordance with current IEE BS...

Page 17: ...ernal thermostat and programmer should be used to control the boiler to schedule the hot water or heating These can be fitted as a single programable thermostat or as an individual programmer and ther...

Page 18: ...owing 7 6 1 1 All STEPS in the manual so far have been completed as instructed The boiler must have been filled with water and isolating valves must be in the open position 7 6 1 2 The boiler casing i...

Page 19: ...e Daily 24hr Timing Menu Key 6 Confirm and exit Fault clear key Actual temperature Heating actual outlet temperature bathroom actual outlet temperature Water pump operation status Lit the pump is runn...

Page 20: ...om setting temperature Fault code In winter mode Shows the heating setting temperature In summer mode Shows the Hot water setting temperature Shows Fault Code when a fault occurs Indoor temperature th...

Page 21: ...nd down arrow buttons set the desired temperature 7 6 2 2 1 Press the On Off key to light up the winter mode icon This will also illuminate the actual setting temperature the actual water outlet tempe...

Page 22: ...at the boiler has started to heat the water 7 7 4 Purge Air from The System With the pump running start to purge all air from the system by bleeding all radiators and air vents Once bled the system sh...

Page 23: ...to 5 degrees above current room temperature and check that the boiler heating fires This is confirmed by the Ignition symbol and the Temperature symbol being solidly lit 8 1 2 Let the boiler run for a...

Page 24: ...HEATING PRESSURE SET AT Bar WHAT IS THE INCOMMING MAINS PRESSURE Bar WHAT HAS THE BOILER FLOW TEMPERATURE BEEN SET AT o C WHAT HAS THE BOILER DIFFERENTIAL TEMP BEEN SET AT o C WHAT PUMP SPEED HAS BEE...

Page 25: ...S THE DRAW OF THE APPLIANCE FOR HOT WATER AMPS WHAT SIZE CABLE WAS INSTALLED TO THE APPLIANCE MM2 WHAT IS THE APPROXIMATE CABLE RUN TO THE BOILER M WHAT TYPE OF CABLE HAS BEEN USED Notes BY SIGNING YO...

Page 26: ...ult Heating water temperature is too low 1 If the heating pipework is frozen the boiler will not be able to work 2 Clean pipeline refill the water then switch on EC Display Disconnected from PCB Displ...

Page 27: ...eck whether the heater has leakage and change it 3 Check whether there is leakage situation in the external input power wires and repair the line Dry burning temperature controller trip Display screen...

Page 28: ...inter mode icon This will also illuminate the actual setting temperature the actual water outlet temperature the thermostat indoor temperature control icon heating icon water pump icon Time heating ic...

Page 29: ...timing segment light off And then press MODE and the flashes Press UP DOWN to set the temperature Long press Clock for 3 seconds until the icon is light and timing function starts 10 8 3 1 24 Time on...

Page 30: ...30 www ehs heating com EHS System Boiler 1 Phase...

Page 31: ...31 www ehs heating com EHS Combination Boiler 1 Phase Circuit Diagram Technical Data...

Page 32: ...630mm 380mm 230mm 12 BOILER MAINTENANCE EHS electric boilers do not require maintenance other than the following The heating system must be filled and maintained when the water is cold between a press...

Page 33: ...the last service without invalidating the Warranty 24 If the service is not carried out in accordance with the guidelines within the product installation manual the Warranty cover will become void 25...

Page 34: ...d chemical treatments inhibitor etc Any repair that is needed because of anything other than a fault to the Boiler or failure of the Boiler itself Any 3rd party damage whether accidental negligent mal...