background image

 

20 

www.ehs-heating.com 

 

 
 
 

There are 3 key parameters that need to be set to make the boiler function correctly: See section on how to set all 

the functions Press ON/OFF button to turn boiler into – Standby/Summer mode

 

7.6.2.1.

 

SET THE CLOCK

 - In Standby Mode 

7.6.2.1.1.

 

Whilst in standby, Press 

 “MODE” key three times. Hour will start flashing 

7.6.2.1.2.

 

Press “UP / DOWN” to adjust the hour setting, 

 

Summer mode 

On--In the summer mode, hot water function is on, but 

heating is off. 

 

Time 

Shows the current 24hr time in hours and the minute. 

 

Timing function 

status 

On—Heating timing is controlled by the boiler. 

Off-- Heating timing is not controlled by the boiler 

 

Heating status 

On--In heating. 

Off--No heating 

 

Heating setting 

temperature, 

Bathroom setting 

temperature, 

Fault code 

In winter mode--Shows the heating setting temperature. 

In summer mode--Shows the Hot water setting temperature. 

Shows Fault Code when a fault occurs. 

 

Indoor temperature 

thermostat 

On--Heating is required when the room temperature 

thermostat is closed 

Off--The room temperature thermostat is disconnected and 

heating is not required 

 

Anti-freezing 

function 

On- Boiler in Anti-freeze mode – heating at 7degrees 

 

Timed period Icon 

When the timing mode is turned on, and the blocks are lit, 

heating is required during the solid periods 

When the timing mode is turned on, and the blocks are blank, 

no heating is required in this period 

 

The heating indicator 

icon 

On and flashing-In heating status 

Off and no flashing-Not in heating status 

 

Fault protection icon  On- Failure protection needs to view the fault code table 

Off- Failure-free 

 

Period display area 

Light up at the specified day of the week. 1~7 

Summary of Contents for ALC1-1PCO12

Page 1: ...EHS Combination and System Boilers Installation Manual Heating for the Renewable Future Please read through the whole instructions before removing the boiler from its packaging and installing and ope...

Page 2: ...ICE UNDER NO CIRCUMSTANCES MUST THIS BOILER BE CONNECTED TO THE MAINS POWER WHILST THE BOILER IS DRY THE BOILER MUST BE FILLED WITH WATER AND PRESSURE TESTED PRIOR TO ELECTRICAL CONNECTION FAILURE TO...

Page 3: ...7 4 1 Flushing 7 4 2 Heating System Fill 7 4 3 Hot Water System Fill 7 5 Electrical Connections 7 5 1 Electricity Connection Precautions 7 5 2 Electrical Supply Connections 7 5 3 Thermostat connectio...

Page 4: ...he boiler at www ehs heating com within the time specified in the warranty terms and conditions This can be found at the back of this manual and on the EHS website The warranty relates to any manufact...

Page 5: ...reaker is used VOLTAGE AND LOAD TEST DONE CABLE SIZE mm BREAKER AMPS 3 6 Check the central heating design is suitable for the application Detailed recommendations are provided in BS EN 12828 and BS EN...

Page 6: ...trical installations IEE Wiring Regulations Seventeenth edition 4 1 7 BS EN 7593 Code of practice for treatment of water in heating systems 5 Unpacking and installation 5 1 These appliances can weigh...

Page 7: ...able Connector 1 4 Single valve 1 14 Water tank pipe 1 24 Body parts 1 5 Pressure switch 1 15 Pressure relief pipe 1 25 Expansion tank 5 litres left side 1 6 Pressure gauge 1 16 Pressure relief valve...

Page 8: ...ponents 1 5 DHW thermostat 60A 17 Water temperature probe D12 1 29 Wire 1 6 Pressure switch 1 18 Water temperature probe D18 1 30 Cable Connector 1 7 Pressure gauge 1 19 Water tank pipe 1 31 Body part...

Page 9: ...the electrical supply then you must install it in a fashion that prevents access to the boiler such as a lockable cupboard The wall that you choose to mount this boiler on should be strong enough to...

Page 10: ...10 www ehs heating com Screw 3 x screws into 3 upper expansion screw bolts Step Four Hang the boiler on the 3 fixed screws Then drill 2 screws into 2 under expansion screws...

Page 11: ...11 www ehs heating com 7 2 Design and connect the plumbing system 7 2 1 Typical S plan Layout for a system boiler...

Page 12: ...12 www ehs heating com 7 2 2 Typical Layout for Combination Boiler...

Page 13: ...d on the flow and return pipework from the boiler Standard ball valves will restrict flow and impede the flow in and out of the boiler which will result in poor performance AUTOMATIC AIRVENTS The EHS...

Page 14: ...red as overtightening of connections can twist and damage the internal pipework of the boiler which is not covered under the warranty An external magnetic filter must be used on all installations 7 3...

Page 15: ...automatic air vent behind the pump in the boiler to ensure its not screwed down It needs to be free moving 7 4 2 3 Connect the filling loop to the water replenishing connection 7 4 2 4 Open the replen...

Page 16: ...carried out when installing high power boilers 7 5 1 2 All electrical connections must be made by a fully qualified electrician 7 5 1 3 All wiring must be carried out in accordance with current IEE BS...

Page 17: ...ernal thermostat and programmer should be used to control the boiler to schedule the hot water or heating These can be fitted as a single programable thermostat or as an individual programmer and ther...

Page 18: ...owing 7 6 1 1 All STEPS in the manual so far have been completed as instructed The boiler must have been filled with water and isolating valves must be in the open position 7 6 1 2 The boiler casing i...

Page 19: ...e Daily 24hr Timing Menu Key 6 Confirm and exit Fault clear key Actual temperature Heating actual outlet temperature bathroom actual outlet temperature Water pump operation status Lit the pump is runn...

Page 20: ...om setting temperature Fault code In winter mode Shows the heating setting temperature In summer mode Shows the Hot water setting temperature Shows Fault Code when a fault occurs Indoor temperature th...

Page 21: ...nd down arrow buttons set the desired temperature 7 6 2 2 1 Press the On Off key to light up the winter mode icon This will also illuminate the actual setting temperature the actual water outlet tempe...

Page 22: ...at the boiler has started to heat the water 7 7 4 Purge Air from The System With the pump running start to purge all air from the system by bleeding all radiators and air vents Once bled the system sh...

Page 23: ...to 5 degrees above current room temperature and check that the boiler heating fires This is confirmed by the Ignition symbol and the Temperature symbol being solidly lit 8 1 2 Let the boiler run for a...

Page 24: ...HEATING PRESSURE SET AT Bar WHAT IS THE INCOMMING MAINS PRESSURE Bar WHAT HAS THE BOILER FLOW TEMPERATURE BEEN SET AT o C WHAT HAS THE BOILER DIFFERENTIAL TEMP BEEN SET AT o C WHAT PUMP SPEED HAS BEE...

Page 25: ...S THE DRAW OF THE APPLIANCE FOR HOT WATER AMPS WHAT SIZE CABLE WAS INSTALLED TO THE APPLIANCE MM2 WHAT IS THE APPROXIMATE CABLE RUN TO THE BOILER M WHAT TYPE OF CABLE HAS BEEN USED Notes BY SIGNING YO...

Page 26: ...ult Heating water temperature is too low 1 If the heating pipework is frozen the boiler will not be able to work 2 Clean pipeline refill the water then switch on EC Display Disconnected from PCB Displ...

Page 27: ...eck whether the heater has leakage and change it 3 Check whether there is leakage situation in the external input power wires and repair the line Dry burning temperature controller trip Display screen...

Page 28: ...inter mode icon This will also illuminate the actual setting temperature the actual water outlet temperature the thermostat indoor temperature control icon heating icon water pump icon Time heating ic...

Page 29: ...timing segment light off And then press MODE and the flashes Press UP DOWN to set the temperature Long press Clock for 3 seconds until the icon is light and timing function starts 10 8 3 1 24 Time on...

Page 30: ...30 www ehs heating com EHS System Boiler 1 Phase...

Page 31: ...31 www ehs heating com EHS Combination Boiler 1 Phase Circuit Diagram Technical Data...

Page 32: ...630mm 380mm 230mm 12 BOILER MAINTENANCE EHS electric boilers do not require maintenance other than the following The heating system must be filled and maintained when the water is cold between a press...

Page 33: ...the last service without invalidating the Warranty 24 If the service is not carried out in accordance with the guidelines within the product installation manual the Warranty cover will become void 25...

Page 34: ...d chemical treatments inhibitor etc Any repair that is needed because of anything other than a fault to the Boiler or failure of the Boiler itself Any 3rd party damage whether accidental negligent mal...

Reviews: