4 Maintenance
restore factory settings
NOtES
• Returning to the pre-configured mode de
-
letes the changes to the leaf priority, the di-
rection of rotation, the closing force setting,
all radio transmitters and sensors, the fa-
vourite position and deactivates the buzzer.
• The end positions are deleted.
• All these parameters of the drive are reset to
the values set by ehret in the delivery state.
open the sashes halfway.
press and hold the
-key
c
on the keypad
for 7 sec. until the sash with cover strip per-
forms an up/down movement and a signal
tone sounds.
c
7 s
beep
After the up/down movement, the pre-config-
ured mode is active again.
restore the initial configuration
NOtES
• Restoring the output configuration deletes
all parameters of the drive. these are the
parameters mentioned in
chapter “list of
setting parameters”, p. 36.
• Restoring the output configuration cannot be
done via a radio transmitter. to return to the
output configuration, the keypad of the drive
must be used.
to restore the initial configuration, press and
hold the
-key
c
on the keypad of the drive
for 15 sec. until a series of beeps sounds for
the second time.
c
15 s
beep
...
beep
the sash with cover strip performs an up/
down movement after seven seconds and
a signal tone sounds, followed by a second
up/down movement and another signal tone
after 15 seconds.
beep
beep
After the second up/down movement, the out-
put configuration is active again.