7
important notes
Installation FaQs
Which parts have been delivered?
• VOLETRONIC io window shutter drive
• Depending on the diagram, 1× or 2× guide
rail and carriage arm
• 1× adhesive buffer, 1× stop buffer, 2× sup
-
port for stop buffer per sash
• Coupling set with coupled window shutters
• Optional support for end piece of window
shutter drive, pair
Which means of attachment are being used?
• The means of attachment are not included in
the scope of delivery!
• The selection of the attachment materials
is oriented towards the mounting bases on
hand, the load-bearing capacities of which
are to be checked before the installation.
observe without limitation the regulations
of the manufacturers of dowel and attach-
ment materials.
WarNINg
Danger of injury/property damage caused
by unsuitable fastening materials
the means of attachment are to be select-
ed in accordance with the load-bearing ca-
pacity of the mounting bases.
How is the VOLEtrONIC io
window shutter
drive mounted?
• First, the installation profile is aligned and
mounted and the drive modules are hooked
into place and attached.
• Then the carriage arms, guide rails and the
stop buffer are mounted, during which the
drive is connected and put into operation
and the priority of the sashes is checked at
the same time that the carriage arms are in-
stalled.
• Afterwards, the coupling rod is cut to size
and mounted in the case of multiple-section
sashes, and, if express hinges are used, then
these are secured.
Electrical installation
WarNINg
Electrical shock (230 V)
NOtES
• The connection (Phase L) must be equipped
with a line safety switch with a maximum
nominal current of 6 a.
• The line safety switch must have a switch-off
capacity of at least 6 ka.
• The prescribed tripping characteristic is B.
• The line switch should be equipped with a
thermal tripping device for overload protec-
tion, furthermore it should have an electro-
magnetic trigger as a protection against short
circuits.
• Other requirements may apply to the instal
-
lation of the line safety switch, depending
on the location. For example, it could be
necessary to use a line safety switch with
additional separation of phase n in order to
switch off all poles. it might possibly also be
necessary to have a residual current circuit
breaker in the system. the standards and the
laws of the respective country with respect
to permanent electrical installations are to be
complied with (e.g. VDe 0100).
• It is recommended that no more than five
drives are secured simultaneously by a single
line safety switch.
• Pursuant to VDE 0100 and/or the statutory
regulations and standards of the respective
country, the permanent electrical installation
must be carried out by a certified electrician.
• According to VDE 0022, the operator and the
installer are responsible for compliance with
the VDe regulations and/or regulations of the
energy supplier.