Notes

the present installation and operating instruc-
tions describe the commissioning of the eHret 
Voletronic io window shutter drive with 
wireless remote control.

carefully read through these operating instruc-
tions prior to commissioning. observe the 
specified process steps and take into account 
the notes and recommendations given. Knowl-
edge of and technically impeccable implemen-
tation of the given safety notes and warnings 
are prerequisite for the safe and proper opera-
tion of the Voletronic io window shutter 
drive. insufficient knowledge at the time of 
commissioning and utilisation leads to the loss 
of any liability claims against eHret GmbH. 
any installation or operation in deviation from 
our installation and operating instructions – ei-
ther in full or in part – will result in the warranty 
becoming void.

installation of the shutters in accordance with 
the eHret window shutter installation instruc-
tions is a prerequisite for the commissioning of 
the eHret Voletronic io window shutter 
drive.

  

Remove the labels stuck to the shutters after 
installation!

these installation and operating instructions 
are addressed to qualified specialist personnel. 
Qualified specialist personnel are persons who 
are familiar with the transport, setup, installa-
tion, commissioning and operation of the prod-
uct and who have appropriate qualifications for 
their work. specialist personnel must know and 
observe the relevant standards and/or guide-
lines. 

these installation and operating instructions 
are a component part of the product and are 
therefore always to be retained until the prod-
uct is disposed of.

these installation and operating instructions 
are to be passed along in the event of the sale 
of this product. this product is in accordance 
with general rules of technology. safety-con-
scious behaviour is necessary for undertaking 
safe commissioning. For this reason, observe 
the following notes.

should you not understand something in these 
installation and operating instructions unam-
biguously, do not fail to contact the specialist 
personnel at eHret GmbH, 77972 Mahlberg 
(Germany).

Summary of Contents for Voletronic io

Page 1: ...Voletronic io Motorisation for window shutters Installation and operating instructions Installation specialist personnel Valid from 03 2021 E 641 4...

Page 2: ...the commissioning of the EHRET VOLETRONIC io window shutter drive Remove the labels stuck to the shutters after installation These Installation and operating instructions are addressed to qualified s...

Page 3: ...rails to the sash 19 Commissioning 20 Cutting the coupling rod to size and mounting it 24 Crimped metal ribbon 25 3 Operation Opening and closing 26 Preferred position my 26 Detecting obstacles and fr...

Page 4: ...stallation instructions Warning Take into account the following notes and warnings in order to avoid dangers and to protect the product Observe the accident prevention regula tions of the Accident Pre...

Page 5: ...ve reached their final position Do not reach into moving parts or closing areas while shutters are opening or closing Make sure that no articles of clothing or body parts are able to be caught by movi...

Page 6: ...as with the following standards EN 60335 1 2012 A1 2019 A11 2014 A13 2017 A14 2019 A2 2019 EN 60335 2 97 2006 A11 2008 A12 2015 A2 2010 EN 62233 2008 EN 62479 2010 EN 301489 1 V2 2 3 2019 EN 301489 3...

Page 7: ...coupling rod is cut to size and mounted in the case of multiple section sashes and if express hinges are used then these are secured Electrical installation Warning Electrical shock 230 V Notes The co...

Page 8: ...you require information about collection points near you Recyclable materials of the machine Reusable material Components Aluminium Shutters Drive housing Coupling Guide rail Fittings Copper Cables Mo...

Page 9: ...e system for a max of 2 sashes per side for the electronic actuati on of window shutters The drive is equipped with tri band bidirec tional io homecontrol and is suitable for all types of window shutt...

Page 10: ...sash M3 6 mm S1 1 1L 1R 2L 2R 2 2 3L 3R 4 Adhesive buffer Shaft seal ring Stop buffer Support for stop buffer Guide rail Carriage arm Variant B Reveal installation on the side Variant C At the bottom...

Page 11: ...441 1 channel 6642 5 channel 6643 Nina io hand held transmitter bidi rectional touch display control 6220 Support for end piece of window shutter drive pair To be used with window shutter models with...

Page 12: ...m or rub against its immediate sur roundings frame masonry etc The resistance of the folding shutter must not exceed a torque of 4 Nm during movement Remove any pre existing locking elements e g shutt...

Page 13: ...he load capacity of the installation sub strates Notes The selection of the fastening method is de pendent on the substrate and is therefore exclusively your own responsibility Note that the lintel mu...

Page 14: ...profile at at least four points Insert the electromechanical module into the frame on the side where the power supply enters Insert the drive modules into the installation profile move them as far as...

Page 15: ...ing of the drive due to insufficient fastening Use security bore hole 2 3_B Security bore hole Insert the electromechanical module into the frame on the side where the power supply enters Insert the d...

Page 16: ...e of installation profile min 5 mm Caution Property damage caused by sliding of the drive due to insufficient fastening Use security bore hole Security bore hole Insert the electromechanical module in...

Page 17: ...arking Cable holder Wiring WARNING Electrical shock 230 V resulting from dam age to cable Protect mains cable against contact with the activated window shutter Caution Impairment of the antenna and th...

Page 18: ...th guide rails on the drive Notes The swivel arms must be fitted in accord ance with one of these two recommenda tions a half open outside the end positions ob serving the sequence of the covered sash...

Page 19: ...uding slats use the 6220 supports for end pieces of window shutter drive with the corresponding S4 screws When selecting screws for window shutters made of wood a decision that is the exclusive respon...

Page 20: ...cation of proper function ing P 23 Activate radio wall transmitter Caution Do not press against the sensitive side of the wireless wall transmitter with the flat of the hand because otherwise unintend...

Page 21: ...hes is correct If the sash with cover strip opens after or closes before the sash without cover strip the priority of the sashes is not correct and must be changed Self learning process Notes The teac...

Page 22: ...exit the drive s self learning mode OFF beep ON The settings are not saved The self learning process must be repeated B Negative feedback from the drive The drive has detected an inappropriate settin...

Page 23: ...e drive emits 2 signal tones and the folding shutter performs an open close movement beep beep The radio wall transmitter is now linked to the drive Verification of proper functioning Opening procedur...

Page 24: ...us 3 35 52 Close the double shutter and mark the centre of rotation of guide lug B Afterwards open the double shutter and measure the distance from A to B A B Close the double shutter and divide the d...

Page 25: ...Pivot bearing 3 locking set screw Crimped metal ribbon only when express hinges are used Notes The express hinges used must be secured against shifting in place as follows after the installation of th...

Page 26: ...n called the prefer red position can be stored in the memory of the VOLETRONIC io shutter drive That position must not correspond to either the open or the closed position EHRET recommends selecting a...

Page 27: ...obstacle recognition protects the VOLETRONIC io against damage and pre vents accidents If a sash encounters an obstacle when opening or closing the folding shutter is automatically stopped and moves...

Page 28: ...arried out after the adjustment has been made Open the sashes halfway Press and hold the Open and Close buttons simultaneously for five seconds until the product performs an open close movement and em...

Page 29: ...e sashes the closing force can be increased to a higher level as follows Activate the new setting mode see page 28 Open the sashes half way Press the buttons and of the wireless wall transmitter simul...

Page 30: ...g to the pre configured mode deletes the changes to the leaf priority the direction of rotation the closing force setting all radio transmitters and sensors the favourite posi tion and deactivates the...

Page 31: ...pre configured mode is active again Radio transmitter io Pure Option Notes As an option the VOLETRONIC io folding shutter drive can also be controlled by means of a io Pure wireless hand held transmi...

Page 32: ...p tional 9 6 V 1600 mAh Notes The emergency battery must be recognised by the drive to be functional It can only be rec ognised when mains voltage is present If the battery is connected without mains...

Page 33: ...Maintenance Insert the battery by placing it in the 5 fas tening hooks provided on the circuit board housing Make sure that the battery is firmly fitted in place Connect the battery to the circuit bo...

Page 34: ...ig ured mode is active again Restore the initial configuration Notes Restoring the output configuration deletes all parameters of the drive These are the parameters mentioned in chapter List of settin...

Page 35: ...s a selection aid see chapter List of setting parameters p 36 At any step you can cancel the current changes by pressing the key c In case of inactivity the display goes into sleep mode after a few se...

Page 36: ...ng shutters with overlapping If these parameters have not been set at the factory they can only be changed after a reset of the drive to the pre configured mode Changing these parameters makes it nece...

Page 37: ...t for drive operation Battery charge low Battery functional Battery fully charged Reserve ERROR code e 0 to J Product status error code If an error occurred during the last operation an error code app...

Page 38: ...emergency battery must be recognised by the drive to be functional It can only be recognised when mains voltage is present If the battery is connected without mains voltage applied it will not functio...

Page 39: ...o its normal state the power supply must be interrupted for 10 sec Then restore the power supply and start a self learning process Error 02 Motor e 2 Drive current of the multiphase motor Error motor...