10. Technical Data 

 

10.1 Dimensions and Weight 
 

Dimensions in Millimeter 

 

 

 

Typ 

KGW 

Weighing 
range 

in kg 

-dead 
weight 

in kg 

B(*) 

number

step 

in kg 

KGW 1 

0- 1000 

69 

545 

107 (150) 

143 

317 

32 

54 

45 

0,5 

KGW 2 

0- 2000 

69 

545 

107 (150) 

143 

317 

32 

54 

45 

KGW 5 

0- 5000 

69 

545 

107 (150) 

143 

317 

32 

54 

45 

KGW 10 

0- 10000 

82 

570 

150 (300) 

143 

317 

46 

65 

69 

KGW 20 

0- 20000 

240 

872 

232 (500) 

143 

472 

52 

83 / 150 

84 / 93 

10 

KGW 30 

0- 30000 

240 

872 

232 (500) 

143 

472 

52 

83 / 150 

84 / 93 

10 

KGW 50 

0- 50000 

580 

1310 

580 

234 

480 

52 

100 

132 

20 

KGW 100 

0- 100000 

1550 

1820 

815 

310 

860 

85 

140 

190 

50 

 

Summary of Contents for KGW 1

Page 1: ...No 900141 May 2006 Digital Crane Scale Type KGW User Manual...

Page 2: ...4 2 Display and Keypad 5 3 Function Keys 5 4 Display Symbols 6 5 Automatic Power off 7 6 IR remote control 7 7 Power supply of electronic device 7 8 Charger Charging 7 9 Accessories 7 10 Technical Dat...

Page 3: ...onform with following harmonized standards EN 45501 EN 50081 part1 according to the provisions of the directive 89 336 EEC electromagnetic compatibility EMC EN 60950 according to the provisions of the...

Page 4: ...ACCIDENT PREVENTION REGULATIONS Keep this instruction manual in operation Pay attention that scale and load are placed correctly Do not use any solvents for cleaning of the crane scale to prevent defe...

Page 5: ...then only sign is displayed Normal operating status weighing mode will be reached again by reducing preload under the 20 limit and power off on switching Function Key for Scales Power Off Switches off...

Page 6: ...by repressing TARE button and GROSS weight is displayed again Function Key for Zero Setting Zero Button Sets display to 0 semi automatic zero setting device Zero setting range 1 3 of nominal capacity...

Page 7: ...x scales verification interval above the nominal capacity range see model type indication plate so display will switch dark and only sign symbol is displayed Normal weighing status is reached again wh...

Page 8: ...gether with the symbol when a tare value was preset by the remote control The shown weight is a Net weight 8 Symbol for Multirange scale Shows if the scale is in range 1 or 2 only when the scale is ad...

Page 9: ...ional data will be transmitted via UHF radio to receiver units see accessories e g a single print out will be activated on the integrated printer of TELEDATA receiver unit 3 Press button for zero sett...

Page 10: ...g function key on scales keypad This function could be set deactivated by factory or in scale setup 9 Non active 10 Non active 11 Enter Button This press button transfers a code max 5 digits which is...

Page 11: ...ighing mode button 5 Hrn 4 Honk relay sounds switches when the limit is reached for 4 seconds default example button 2 example Hrn 2 Changes the duration to 2 seconds button no duration of sound switc...

Page 12: ...er supply as accumulators supplied by manufacturer Colour code of supply leads plus red minus black 8 Charger Charging It is only allowed to charge the accumulator by original provided EHP charger eit...

Page 13: ...t Bottom side of scales battery housing Picture 8 3 Scales plug socket with charging plug Charger Charging plug to connect with scales charging socket Charging plug to connect battery directly 12V Bat...

Page 14: ...ted in closed rooms and must be protected against moisture 8 3 Function of the LED 8 4 Set into operation Compare the rated voltage of identification plate of charger with the rated voltage of the bat...

Page 15: ...er storage periods 2 possibilities A Disconnect battery from charger and store it fully charged CAUTION Charge battery for min 36 hours before storage period of 3 months or more B You can leave batter...

Page 16: ...ansmission Crane scale type LK LKe can be equipped with a radio transmitter for data transmission on receiver units Teledata Telebox Plus Greybox und Large Display or connection to computer directly L...

Page 17: ...317 32 54 45 0 5 KGW 2 0 2000 69 545 107 150 143 317 32 54 45 1 KGW 5 0 5000 69 545 107 150 143 317 32 54 45 2 KGW 10 0 10000 82 570 150 300 143 317 46 65 69 5 KGW 20 0 20000 240 872 232 500 143 472...

Page 18: ...Ah Min voltage of the accumulators 10 8V DC Supply voltage of the IR remote control 4pcs 1 5V Type AAA Micro LR03 AM4 MN2400 Range of the IR remote control approx 35m with an angle 20 Runtime Approx 1...

Page 19: ...r 12V 13Ah for KGW 1 10 59860 Maintenance free accumulator 12V 20Ah for KGW 15 100 59554 Current supply cable with round plugs 78353 Complete digital display electronic 55385 Fuse holder 52525 Fuse 1A...

Page 20: ...flashes The crane scale is overloaded Reduce the weight on the crane scale The permissible maximum weight is indicated on the identification plate High overload on the crane scale Reduce immediately t...

Page 21: ...the crane scale After 5 seconds the crane scale will switch off automatically Errorcode Cause Solution 02 The input voltage of the amplifier is too small Switch the crane scale off and then on Inform...

Page 22: ...B hl Baden Tel 49 0 7223 93660 Fax 49 0 7223 30140 E mail info ehp de www ehp de servizio post vendita after sales service service apres vente Kundendienstservice servicio post venta servi o p s vend...