6.1 Adjusting the limit values / honk  / relay control  (optional accessories) 

 

limit values (will be stored non volatilely) 

Remote control 

Display 

comment 

 (ENTER) 

AL 

Menu for entering the limt values, with  next 

 back to weighing 

mode 

 (button 1) 

L1 

Limit value 1 

 (ENTER) 

00000 

Entering the limit value 1 

example

 

 

 

 

00500 

Example for value 1 (= 500kg) 

(after 5 seconds without any  input, display jumps back to menu „AL“!) 

 (ENTER) 

00500 

Storing the input (

Æ

 display is flashing!) 

  

AL 

display goes back to „limit-menu“.   Input for the values 2, 3 and 4 

with the buttons 

 und 

 or go back with 

  to the 

weighing mode. 

 

Duration of honk / duration of relay switching  (will be stored non volatile) 

 (ENTER) 

AL 

Menu for entering the limt values, with  next 

 back to 

weighing mode 

 (button 5) 

Hrn  4 

Honk/relay sounds/switches when the limit is reached for 4 
seconds (default) 

example: 

 (button 2) 

example: 

Hrn  2 

Changes the duration to 2 seconds 

(button no. =  duration of sound/switching in seconds  1…9  possible) 

important for relay control : Hrn 0  is switching the relay  as long as the limit is 
reached 

 (ENTER) 

Hrn  2 

input will be stored (

Æ

 display is flashing!) 

 

AL 

display goes back to limit menu for entering the next instruction 

or to go back with 

 to weighing mode 

 

Autotare at limit (will be stored volatile!) 

 (ENTER) 

AL 

Menu for entering the limt values, with  next 

 back to 

weighing mode 

 (button 

tAr  0 

Autotareis is not active 

(button 1 to activate the function  button 0 to de-activate

 

 (button 

tAr  1 

Autotare when reaching the limit value is activated 

 (ENTER) 

tAr  1 

Storing the input (

Æ

 display is flashing) 

 

AL 

display goes back to limit menu for entering the next instruction 

or to go back with 

 to weighing mode 

 

Summary of Contents for KGW 1

Page 1: ...No 900141 May 2006 Digital Crane Scale Type KGW User Manual...

Page 2: ...4 2 Display and Keypad 5 3 Function Keys 5 4 Display Symbols 6 5 Automatic Power off 7 6 IR remote control 7 7 Power supply of electronic device 7 8 Charger Charging 7 9 Accessories 7 10 Technical Dat...

Page 3: ...onform with following harmonized standards EN 45501 EN 50081 part1 according to the provisions of the directive 89 336 EEC electromagnetic compatibility EMC EN 60950 according to the provisions of the...

Page 4: ...ACCIDENT PREVENTION REGULATIONS Keep this instruction manual in operation Pay attention that scale and load are placed correctly Do not use any solvents for cleaning of the crane scale to prevent defe...

Page 5: ...then only sign is displayed Normal operating status weighing mode will be reached again by reducing preload under the 20 limit and power off on switching Function Key for Scales Power Off Switches off...

Page 6: ...by repressing TARE button and GROSS weight is displayed again Function Key for Zero Setting Zero Button Sets display to 0 semi automatic zero setting device Zero setting range 1 3 of nominal capacity...

Page 7: ...x scales verification interval above the nominal capacity range see model type indication plate so display will switch dark and only sign symbol is displayed Normal weighing status is reached again wh...

Page 8: ...gether with the symbol when a tare value was preset by the remote control The shown weight is a Net weight 8 Symbol for Multirange scale Shows if the scale is in range 1 or 2 only when the scale is ad...

Page 9: ...ional data will be transmitted via UHF radio to receiver units see accessories e g a single print out will be activated on the integrated printer of TELEDATA receiver unit 3 Press button for zero sett...

Page 10: ...g function key on scales keypad This function could be set deactivated by factory or in scale setup 9 Non active 10 Non active 11 Enter Button This press button transfers a code max 5 digits which is...

Page 11: ...ighing mode button 5 Hrn 4 Honk relay sounds switches when the limit is reached for 4 seconds default example button 2 example Hrn 2 Changes the duration to 2 seconds button no duration of sound switc...

Page 12: ...er supply as accumulators supplied by manufacturer Colour code of supply leads plus red minus black 8 Charger Charging It is only allowed to charge the accumulator by original provided EHP charger eit...

Page 13: ...t Bottom side of scales battery housing Picture 8 3 Scales plug socket with charging plug Charger Charging plug to connect with scales charging socket Charging plug to connect battery directly 12V Bat...

Page 14: ...ted in closed rooms and must be protected against moisture 8 3 Function of the LED 8 4 Set into operation Compare the rated voltage of identification plate of charger with the rated voltage of the bat...

Page 15: ...er storage periods 2 possibilities A Disconnect battery from charger and store it fully charged CAUTION Charge battery for min 36 hours before storage period of 3 months or more B You can leave batter...

Page 16: ...ansmission Crane scale type LK LKe can be equipped with a radio transmitter for data transmission on receiver units Teledata Telebox Plus Greybox und Large Display or connection to computer directly L...

Page 17: ...317 32 54 45 0 5 KGW 2 0 2000 69 545 107 150 143 317 32 54 45 1 KGW 5 0 5000 69 545 107 150 143 317 32 54 45 2 KGW 10 0 10000 82 570 150 300 143 317 46 65 69 5 KGW 20 0 20000 240 872 232 500 143 472...

Page 18: ...Ah Min voltage of the accumulators 10 8V DC Supply voltage of the IR remote control 4pcs 1 5V Type AAA Micro LR03 AM4 MN2400 Range of the IR remote control approx 35m with an angle 20 Runtime Approx 1...

Page 19: ...r 12V 13Ah for KGW 1 10 59860 Maintenance free accumulator 12V 20Ah for KGW 15 100 59554 Current supply cable with round plugs 78353 Complete digital display electronic 55385 Fuse holder 52525 Fuse 1A...

Page 20: ...flashes The crane scale is overloaded Reduce the weight on the crane scale The permissible maximum weight is indicated on the identification plate High overload on the crane scale Reduce immediately t...

Page 21: ...the crane scale After 5 seconds the crane scale will switch off automatically Errorcode Cause Solution 02 The input voltage of the amplifier is too small Switch the crane scale off and then on Inform...

Page 22: ...B hl Baden Tel 49 0 7223 93660 Fax 49 0 7223 30140 E mail info ehp de www ehp de servizio post vendita after sales service service apres vente Kundendienstservice servicio post venta servi o p s vend...

Reviews: