Note:
Renew the blue filter mat after the third cleaning.
8.1
Prefilter cleaning
1. Disconnect the power cable (31). 2. Disassemble the safety adapter (13) and the pump head (17) (chapter
3, step 1 - 3). 3. Remove the prefilter (4). 4. Remove the blue filter mat (1). 5. Rinse the blue filter mat (1)
under running, lukewarm water (replace if required). 6. Empty the prefilter (4) and rinse it. 7. Insert the blue
filter mat (1) into the prefilter (4). 8. Insert the prefilter (4) with the blue filter mat (1) (place onto supports
fi
arrows). 9. Check and, if required, clean the seals and treat them with EHEIM care spray (No.
4001000). 10. The prefilter flap (3) must be unobstructed. 11. Attach the pump head (17) (observe fitting
position) and close the locking clips (8). 12. Put the filter system into operation (chapter 5, step 17 - 23).
1. Disconnect the power cable (31). 2. Disassemble the safety adapter (13) and the pump head (17) (chapter
3, step 1 - 3). 3. Remove the pre-filter (3), the filter cartridge with the screened cover and white filter fleece.
Renew the white filter fleece (6) during each cleaning process. 4. Remove all filter inserts. 5. Rinse the filter
inserts (7) and filter media with water until they are clean (see EASY CLEAN function). 6. Empty the filter tank (9).
Note:
Only carry out steps 7 to 8 during every third to fourth general cleaning. By mixing used and new sub-
strate media, the required bacteria cultures remain intact.
Caution:
Do not overfill filter inserts as, otherwise, their accurate fit is no longer assured.
7. Leave one-third of the used EHEIM SUBSTRAT
pro
and EHEIM bioMECH in the filter cartridge. 8. Re-fill two-
thirds of the used EHEIM SUBSTRAT
pro
and EHEIM bioMECH. 9. If required, completely renew EHEIM
MECH
pro
. 10. Re-insert all filters and filter inserts (chapter 5, step 8 - 10). 11. Clean the hose system using
an EHEIM universal cleaning brush (No. 4005570). 12. Insert the prefilter (4) with the blue filter mat (1) (place
onto supports
fi
arrows). 13. The prefilter flap (3) must be unobstructed. 14. Check and, if required, clean the
seals and treat them with EHEIM care spray (No. 4001000). 15. Attach the pump head (17) (observe fitting posi-
tion) and close the locking clips (8). 16. Put the filter system into operation (chapter 5, step 17 - 23).
8.2
General cleaning
Caution:
The caramic axis may break. Clean carefully!
1. Disassemble the safety adapter (13) and the pump head (17) (chapter 3, step 1 - 3). 2. Turn the pump
cover (23) and remove it. 3. Disassemble the pump wheel (22). 4. Clean the pump chamber, pump cover,
pump wheel and lubrication duct with the EHEIM cleaning set (No. 4009560). 5. The pump wheel (22) must
be clean and unobstructed (see arrows). Observe the installation position of the ceramic sleeve (a) (only
in
professionel 5e
- 350 Type 2274). 6. Insert the pump wheel (22) into the pump chamber. 7. Close the
pump chamber with the pump cover (23) observing the cutout and studs (arrows). 8. Disassemble the bracket
(14) and the float (15) on the top side of the pump head (17) and clean them. 9. Install the check valve
(14 / 15) (observing the installation position; the float must be unobstructed). 10. Attach the pump head (17)
(observe fitting position) and close the locking clips (8). 11. Put the filter system into operation (chapter 5,
step 17 - 23).
8.3
Cleaning the pump chamber
24
. . . Top part of filter can’t be closed?
9 What to do if . . .
Cause Solution
Filter inserts have been inserted wrongly. Push filter inserts and pre-filter in until they lie flush on top of each other.