background image

4

Natural stone and ceramic tiles

Possible residual moisture in the sub-floor may rise to the surface and consequently, before installing the system-specific insulating 
underlay (see section: 

Attention!

 underlay materials), a moisture protection film, SD value ≥ 75 m, must be installed over the whole 

area in a trough shape as a moisture barrier. When installing EGGER Laminate flooring with Silenzio underlay laminated to the back 
and Comfort flooring, no other insulating underlay must be installed.

Woodchip and fibreboard

To improve impact sound, before installing laminate flooring a system-specific insulating underlay (see section: 

Attention!

 Underlay 

materials) should be installed. A moisture protection film (vapour barrier) should not be fitted. EGGER Laminate flooring with 
Silenzio underlay laminated to the back and Comfort flooring can be directly installed on wooden boards.

Wooden boards

Any loose boards should be properly screwed down. To improve impact sound, before installing laminate flooring a system-specific 
insulating underlay (see section: 

Attention!

 Underlay materials) should be installed. A moisture protection film (vapour barrier) 

should not be fitted. EGGER Laminate flooring with Silenzio underlay laminated to the back and Comfort flooring can be directly 
installed on floorboards. Please note that the laminate flooring and Comfort flooring elements are installed at right angles to the 
floorboards.

Elastic flooring surfaces (PVC, linoleum, vinyl)

The use of flexible floor coverings meets the damp-proofing requirements and thus eradicates the need for a moisture protection 
film. To improve impact sound, before installing laminate flooring, a system-specific insulating underlay should be installed. EGGER 
Laminate flooring with Silenzio underlay laminated to the back and Comfort flooring, can be directly installed on the elastic flooring. 
(see section: 

Attention!

 Underlay materials)

Wet rooms / wet areas

Attention!

 EGGER Laminate and Comfort flooring may not be installed in wet and damp rooms such as bathrooms, saunas or similar 

spaces. In the case of failure to comply, all guarantee and warranty claims will become void.

Attention! Underlay materials

 

ƒ

On mineral sub-floors, a moisture protection film, SD value ≥ 75 m, must be installed over the whole area in a trough shape. 
The exception to this is when using EGGER Silenzio Duo (2 in 1 insulating underlay with integrated moisture protection) or a 
comparable 2 in 1 underlay. In these cases, a separate moisture protection film is not necessary.

 

ƒ

A system-specific EGGER Silenzio underlay must be used under EGGER laminate flooring. Alternative underlayer boards are 
available at 

www.egger.com

 

ƒ

The exception to this is when using EGGER laminate flooring with Silenzio underlay laminated to the back and Comfort 
flooring. No other insulating underlay must be used in this case.

Sub-floors

Summary of Contents for UNIfit!

Page 1: ...Installation instructions for Egger Laminate and Comfort flooring with UNIfit installation system...

Page 2: ...M For calcium sulphate screeds calcium sulphate floating screeds 0 5CM heated screeds 0 3CM These values apply to screeds without additives With the use of additives and in case of fast setting screed...

Page 3: ...heating engineer installer floor covering manufacturer must work together in a coordinated manner All surface heated flooring requires appropriate planning and coordination of the heating system and s...

Page 4: ...nate flooring and Comfort flooring elements are installed at right angles to the floorboards Elastic flooring surfaces PVC linoleum vinyl The use of flexible floor coverings meets the damp proofing re...

Page 5: ...one at right angles to the boarding or the direction of the strip parquet wooden floor Planning the first row First the room must be measured to determine whether the width of the first row should be...

Page 6: ...sides of both elements push against each other and fits perfectly Once again lock the longitudinal connection by lowering and at the same time the frontal connection by pushing until you can feel the...

Page 7: ...leftover piece of the previous row if this is at least 200mm long or 500mm for Long format floor boards You can continue to install board after board now In order to prepare the last row of boards for...

Page 8: ...and tapping block Figure 1b 1c On door frames that cannot be shortened e g made of metal the fitted expansion joint must be sealed or covered with an elastic jointing material or suitable end profile...

Page 9: ...ort flooring immediately Steam cleaners should not be used the exception being on Aqua Laminate Flooring Only clean laminate and Comfort flooring with a damp cloth Never use scouring or abrasive mater...

Page 10: ...3841 301 20222 flooring egger com EGGER Drevprodukt Gagarin Ezhvinsky proezd 1 215010 Gagarin Oblast Smolensk Russia T 7 48135 79 300 F 7 48135 79 311 info ru egger com EN_EGGER_flo_installation_inst...

Reviews: