3

2.2

All sub-floors, which are deemed to be ready for installation and meet the requirements previously listed, are suitable for installing 
EGGER Laminate and Comfort flooring as a floating installation. This includes:

 

ƒ

All types of screed including hot water-heated screed

 

ƒ

Chipboard constructions

 

ƒ

Fibreboards

 

ƒ

Existing floor coatings such as PVC, linoleum, natural stone slabs and ceramic tiles.

Unsuitable sub-floors:

EGGER Laminate and Comfort flooring must never be installed on textile floor coverings (e.g. carpet) or sub-floors that are not ready 
for installation. In the case of failure to comply, all guarantee and warranty claims will become void.

Sub-floors of limited suitability include:

 

ƒ

Electrically operated underfloor heating (controlling the surface temperature). 

Electrical underfloor heating systems are classified as sub-floors with limited suitability. This is because a range of film-based, 
electrical heating systems are able to generate surface temperatures that significantly exceed 28° C. EGGER approves the use of 
an electrically operated underfloor heating system if it can be controlled digitally and the surface temperature can never exceed 
28° C. The technical approval must have been granted by the manufacturer of the heating system for EGGER Laminate and Comfort 
flooring.

Screed

When installing EGGER Laminate and Comfort flooring as a floating installation on screeds, it should be noted that rising damp must 
be expected. Consequently, all types of screed (with the exception of mastic asphalt) require, prior to the installation of a system-
specific insulating layer (see section: 

Attention!

 underlay materials), a moisture protection film, SD value ≥ 75 m, to be installed over 

the whole area in a trough shape as a moisture barrier. When professionally installed, the strips of the moisture protection film must 
overlap by 5 - 20 cm at the joints depending on the version.

Screeds with hot water floor heating

When preparing a heated flooring design, all those involved (builder, architect, specialist heating planner, heating engineer, 
installer, floor covering manufacturer) must work together in a coordinated manner. All surface-heated flooring requires appropriate 
planning and coordination of the heating system and screed in order to ensure maximum long-term performance without causing 
any damage. Alongside the usual checks on the installation sub-floor, the underfloor heating / cooling function must be checked 
(functional heating / cooling). This evidence of the screed construction being properly heated up and cooled down must be provided 
each season and be documented.

When heating the load and heat distribution layer, a distinction is made between functional heating and floor curing heating.

 

ƒ

Functional heating is the heating engineer’s evidence of preparing a job free of defects and is used to review the proper 
functioning of the heating floor structure.

 

ƒ

Floor curing heating is the expelling of the residual moisture in the screed until installation suitability is reached.

Attention!

 Functional heating does not guarantee that the screed has reached the residual moisture required for installation 

suitability. Accordingly, floor curing heating is necessary as a rule.

Attention!

 The surface temperature of a heated floor structure may not exceed 28° C (83° F). EGGER Laminate and Comfort flooring is 

generally laid as a “floating” installation. On mineral sub-floors it is essential to install a moisture protection film, SD value ≥ 75 m, 
over the whole area in a trough shape as a moisture barrier before the insulating underlay. When installing laminate flooring as a 
floating installation, attention should be paid to the heat conductivity values of the laminate flooring and the insulating underlay. 
The total of the heat conductivity values for all components must be ≤ 0.15 m²K/W according to the CE requirement. When using 
insulating underlays that are not from the EGGER range of accessories, any guarantee is rejected with regards to compliance with the 
effective maximum permitted heat conductivity of the overall structure for a floating installation on heated screeds. When installing 
EGGER Laminate flooring with Silenzio underlay laminated to the back and Comfort flooring, no other insulating underlay must be 
installed.

Sub-floors

Summary of Contents for UNIfit!

Page 1: ...Installation instructions for Egger Laminate and Comfort flooring with UNIfit installation system...

Page 2: ...M For calcium sulphate screeds calcium sulphate floating screeds 0 5CM heated screeds 0 3CM These values apply to screeds without additives With the use of additives and in case of fast setting screed...

Page 3: ...heating engineer installer floor covering manufacturer must work together in a coordinated manner All surface heated flooring requires appropriate planning and coordination of the heating system and s...

Page 4: ...nate flooring and Comfort flooring elements are installed at right angles to the floorboards Elastic flooring surfaces PVC linoleum vinyl The use of flexible floor coverings meets the damp proofing re...

Page 5: ...one at right angles to the boarding or the direction of the strip parquet wooden floor Planning the first row First the room must be measured to determine whether the width of the first row should be...

Page 6: ...sides of both elements push against each other and fits perfectly Once again lock the longitudinal connection by lowering and at the same time the frontal connection by pushing until you can feel the...

Page 7: ...leftover piece of the previous row if this is at least 200mm long or 500mm for Long format floor boards You can continue to install board after board now In order to prepare the last row of boards for...

Page 8: ...and tapping block Figure 1b 1c On door frames that cannot be shortened e g made of metal the fitted expansion joint must be sealed or covered with an elastic jointing material or suitable end profile...

Page 9: ...ort flooring immediately Steam cleaners should not be used the exception being on Aqua Laminate Flooring Only clean laminate and Comfort flooring with a damp cloth Never use scouring or abrasive mater...

Page 10: ...3841 301 20222 flooring egger com EGGER Drevprodukt Gagarin Ezhvinsky proezd 1 215010 Gagarin Oblast Smolensk Russia T 7 48135 79 300 F 7 48135 79 311 info ru egger com EN_EGGER_flo_installation_inst...