8
Installation
Pipes
1
3
2
4
Measure the position of the pipes and mark it on the panel (allow for edge joint).
Drill at least 16 mm more than the diameter of the pipe.
Saw the holes at a 45° angle.
Fit and glue the sawn piece.
Door frames
1a
1b
1c
= +
16 mm
a
b
c
2
If there are wooden door frames, it is recommended to shorten these by the installation height (flooring plus underlay materials)
in consultation with the customer. (Figure 1a)
Then install laminate or Comfort flooring under the frame with an appropriate expansion joint. In case the installation takes you to
a door frame, the respective board can be angled longitudinally and lowered. Subsequently, the element placed flat on the floor
is pushed under the door frame and the frontal connection is locked through horizontal knocking with a hammer and tapping
block. (Figure 1b + 1c)
On door frames that cannot be shortened, e.g. made of metal, the fitted expansion joint must be sealed or covered with an elastic
jointing material or suitable end profiles. (Figure 2)
Flooring profiles and skirting boards
After finishing the professional installation of the laminate or Comfort flooring, both the necessary flooring profiles and skirting
boards are fitted. Simple assembly instructions are enclosed with all the accessories.
Attention!
With most types of profile, it is necessary to fit the base (sub-profile) to take the cover profile before installing laminate
and Comfort flooring.
Removal / Dismantling of Boards
To replace boards already installed without damaging them, you must firstly loosen the entire row on the long side from the locking
mechanism by bending it and then pushing the boards parallel against each other on the short side whilst they are flat on the
ground. Proceed with due care in order to avoid damaging the tongue and groove.
a
b
c