Data Interface and Optional Accessories
Page 88
Write only (Function code 0x10)
Address
Name
Description
Value
Type
41016
Cartridge Reset
Reset fuel gauge of car-
tridge port to 100 %.
C: Connector
DCS1: DuoCartSwitch DCS1
1: C#1
11: C#1 DCS1#1
12: C#1 DCS1#2
2: C#2
21: C#2 DCS1#1
22: C#2 DCS1#2
-1 : All
INT16
41996
Modbus Address
Set Modbus address
1 - 247
INT16
41998
Modbus Config
Set Modbus communication
settings.
0: 9600 8,E,1
1: 9600 8,O,1
2: 9600 8,N,2
3: 9600 8,N,1
INT16
42000
Reset
Restart the fuel cell
0xBEAF
INT16
42002
Factory Defaults
Set all parameters to de-
fault
0xBEAF
INT16
42004
Hybrid
Deactivate all parameters.
0 : signal off
1 : signal on
INT16
42006
Plain text Proto-
col
Switch device to plain text
interface.
0xBEAF
INT16
49999
IDSTATESEL
Select expert setting read
property of selected ID.
See chapter 8.2.1.2 “Over-
view ID list” on page 91.
0: selected value
1: default value
2: min value
3: max value
INT16