Permitted value ranges for LiFePO4 batteries (12 V)
ID
Factory
defaults
Min.
Max.
User-de-
fined
value:
Switch-on voltage
25
12.6 V
12.0 V
13.4 V
Switch-off voltage
26
14.5 V
13.8 V
14.6 V
Switch-off voltage (Hybrid)
76
14.6 V
13.5 V
15.5 V
Switch-off current
27
EFOY Pro 800
EFOY Pro 2400
2.0 A
4.0 A
0.5 A
2.0 A
10.0 A
10.0 A
Switch-on delay
17
60 s
2 s
300 s
Absorption time
45
180 min
0 min
300 min
Min. charge time
89
30 min
30 min
180 min
Max. charge time
77
48 h
2 h
120 h
Altitude up to
24
1500 m
0 m
2000 m
Permitted value ranges for lead batteries (24 V)
ID
Factory
defaults
Min.
Max.
User-de-
fined
value:
Switch-on voltage
21
24.6 V
22.0 V
26.0 V
Switch-off voltage
22
28.4 V
27.0 V
29.4 V
Switch-off voltage (Hybrid)
75
29.4 V
27.0 V
31.0 V
Switch-off current
23
EFOY Pro 800
EFOY Pro 2400
1.0 A
2.0 A
0.25 A
1.0 A
5.0 A
5.0 A
Switch-on delay
17
60 s
2 s
300 s
Absorption time
45
180 min
0 min
300 min
Min. charge time
89
30 min
30 min
180 min
Max. charge time
49
24 h
2 h
120 h
Altitude up to
24
1500 m
0 m
2000 m